{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1196-3ED22-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1196-3ED22-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1196-3ED22-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1196-3ED22-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON molded case circuit breaker, 2-pole, 16 A rated current, 75.6 kA breaking capacity at 240 V AC, TM210 thermal-magnetic trip, line protection design, IP40 front, active production.","salesMarkdown":"The Siemens SENTRON 3VA1196-3ED22-0AA0 is a 2-pole molded case circuit breaker rated for 16 A continuous duty across a 40 °C to 55 °C ambient range, with a thermal-magnetic TM210 overcurrent release. Breaking capacity hits 75.6 kA at 240 V AC and 52.5 kA at 415 V AC, so it handles high-fault utility feeds without needing an upstream current-limiting fuse. At 70 °C ambient the rating drops to 15 A — still a solid 15 A, but if your panel runs hot near a transformer or drive, size the load accordingly. Insulation voltage is 500 V, operating voltage 415 V AC or 250 V DC, so it covers most industrial control panels and lighting distribution boards. The case measures 50.8 mm wide, 130 mm tall, 70 mm deep — a 2-inch wide footprint that fits standard panel-mount cutouts for 2-pole MCCBs.","metaTitle":"Siemens 3VA1196-3ED22-0AA0 SENTRON MCCB, 2-Pole, 16A, 75.6kA","metaDescription":"Siemens 3VA1196-3ED22-0AA0 SENTRON 2-pole molded case circuit breaker, 16A rated, 75.6kA at 240V breaking capacity. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"50.8 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 40 °C":"16 A","at 45 °C":"16 A","at 50 °C":"16 A","at 55 °C":"16 A","at 60 °C":"15 A","at 65 °C":"15 A","at 70 °C":"15 A","Depth [In]":"2.76 in","Width [In]":"2 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"2","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"7.06 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"500 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"415 V","operating voltage / at DC / rated value":"250 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"N","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$80.01","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e8ff4b3257a8d3fe66c454165a371d53.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=229003&mlfb=3VA1196-3ED22-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1196-3ED22-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA1196-3ED22-0AA0?","answer":"75.6 kA at 240 V AC and 52.5 kA at 415 V AC — high enough for most industrial service entrances and distribution panels without needing a current-limiting fuse upstream."},{"question":"What is the closest functional second-source for 3VA1196-3ED22-0AA0?","answer":"The 3VA1110-5ED32-0AA0 is a similar 2-pole SENTRON MCCB but with a different trip unit and current rating. It shares the same frame dimensions but the trip curve and ampacity differ — verify load coordination before substituting."},{"question":"How do I get current pricing and availability for 3VA1196-3ED22-0AA0?","answer":"Submit an RFQ through this page. We source it against your order; availability and price are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1196-3ED22-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1196-3ED22-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}