{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1196-3GE42-0AA0-ZD00","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1196-3GE42-0AA0-ZD00","canonicalUrl":"https://aoctrl.com/siemens/3VA1196-3GE42-0AA0-ZD00","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1196-3GE42-0AA0-ZD00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 160, breaking capacity class N, 4-pole, 16 A, Icu = 25 kA @ 415 V, line protection TM220, ATFM, N conductor protection 100%, nut keeper kit for DC Power OEM in China.","salesMarkdown":"The Siemens 3VA1196-3GE42-0AA0-ZD00 is a 4-pole IEC frame 160 molded-case circuit breaker with a 16 A rating and a 25 kA Icu at 415 V (breaking capacity class N). The TM220 thermal-magnetic trip unit provides adjustable overload protection (Ir = 11 A to 16 A) and a fixed short-circuit pickup of 20 x In. The N conductor is protected at 100 %, and the unit includes a nut keeper kit for DC Power OEM applications in China.","metaTitle":"Siemens 3VA1196-3GE42-0AA0-ZD00 Circuit Breaker, 16A, 25kA @","metaDescription":"Siemens 3VA1196-3GE42-0AA0-ZD00 IEC frame 160 circuit breaker, 4-pole, 16A, 25kA Icu @ 415V. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6044cbbcd8ef0547692f741d16d394da.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1667874&mlfb=3VA1196-3GE42-0AA0-ZD00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1196-3GE42-0AA0-ZD00/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for 3VA1196-3GE42-0AA0-ZD00?","answer":"It is a 4-pole IEC frame 160 breaker rated 16 A with a 25 kA Icu at 415 V (breaking capacity class N). Overload protection is adjustable from 11 A to 16 A, and short-circuit pickup is fixed at 20 x In."},{"question":"Where can I buy 3VA1196-3GE42-0AA0-ZD00?","answer":"We source this part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no maverick spend on one-off requisitions."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1196-3GE42-0AA0-ZD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1196-3GE42-0AA0-ZD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}