{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1196-4ED12-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1196-4ED12-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1196-4ED12-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1196-4ED12-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1 series, Molded case circuit breaker (MCCB), 3VA1196-4ED12-0AA0, 1-pole, 16 A rated at 40 °C, TM210 thermal-magnetic release, 75.6 kA breaking capacity at 240 V AC.","salesMarkdown":"It carries a continuous current rating of 16 A at 40 °C (derating to 15 A at 60 °C and above), with a TM210 thermal-magnetic release that provides fixed overload and short-circuit protection curves suited for feeder and branch circuits in industrial panels. The interrupting rating is 75.6 kA at 240 V AC and 9 kA at 415 V AC — a wide gap that tells you this breaker is optimized for 240 V line-to-neutral or line-to-ground fault duty typical in North American split-phase panels, not for 400 V three-phase feeders where the 9 kA figure governs. At 415 V the 9 kA SCCR is modest; coordinate downstream to avoid cascading trip if fault current exceeds that level. Width is 25.4 mm (1 inch) — a single pole module that snaps onto standard DIN rail. Depth is 70 mm, height 130 mm.","metaTitle":"Siemens 3VA1196-4ED12-0AA0 SENTRON MCCB, 16 A, 1-Pole, TM210","metaDescription":"Siemens 3VA1196-4ED12-0AA0 SENTRON molded case circuit breaker, 16 A at 40 °C, 1-pole, 75.6 kA breaking at 240 V. Current production. Sourced to order. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"25.4 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"75.6 kA","at 415 V":"9 kA","at 40 °C":"16 A","at 45 °C":"16 A","at 50 °C":"16 A","at 55 °C":"16 A","at 60 °C":"15 A","at 65 °C":"15 A","at 70 °C":"15 A","Depth [In]":"2.76 in","Width [In]":"1 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"1","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"3.53 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"500 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"415 V","operating voltage / at DC / rated value":"125 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"S","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4596f3e74672a1d9eceba11904841021.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=113529&mlfb=3VA1196-4ED12-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1196-4ED12-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA1196-4ED12-0AA0 at 240 V?","answer":"75.6 kA at 240 V AC, which is the headline interrupting rating for this 1-pole breaker."},{"question":"What is the width of 3VA1196-4ED12-0AA0?","answer":"25.4 mm (1 inch), a single-pole module width for DIN-rail mounting."},{"question":"Where can I buy 3VA1196-4ED12-0AA0 and get current pricing?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1196-4ED12-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1196-4ED12-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}