{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1196-4ED36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1196-4ED36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1196-4ED36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1196-4ED36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1196-4ED36-0AA0, molded case circuit breaker, 3-pole, 16 A, TM210 thermal-magnetic release, 121 kA at 240 V, 75.6 kA at 415 V.","salesMarkdown":"The TM210 thermal-magnetic release gives it adjustable short-circuit pickup at 320 A (fixed, not a range), so it clears bolted faults fast while riding through motor inrush on the thermal side. The interrupting ratings tell the real story: 121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V — meaning it handles high available fault current on 480 V or 600 V class distribution without cascading upstream. Thermal derating is minimal through 55 °C — still 16 A — then drops to 15 A at 60 °C through 70 °C. That means in a warm panel (say 50 °C ambient) you get full ampacity; above 55 °C you lose 1 A. At 76.2 mm wide (3 in), 130 mm tall, and 70 mm deep, this 3-pole MCCB fits standard SENTRON mounting footprints. An optional motor drive (product extension available) allows remote trip or reset.","metaTitle":"Siemens 3VA1196-4ED36-0AA0 SENTRON MCCB, 16 A, 3-Pole, 121 k","metaDescription":"Siemens SENTRON 3VA1196-4ED36-0AA0 molded case circuit breaker, 16 A, 3-pole, TM210 release, 121 kA at 240 V. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"121 kA","at 415 V":"75.6 kA","at 440 V":"52.5 kA","at 500 V":"11.9 kA","at 690 V":"11.9 kA","at 45 °C":"16 A","at 50 °C":"16 A","at 55 °C":"16 A","at 60 °C":"15 A","at 65 °C":"15 A","at 70 °C":"15 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Number Of Poles":"3","Product version":"Line protection","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10.6 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"16 A","Ground-Fault Monitoring Version":"Without","Tension assignée d'isolement Ui":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","reference code / acc. to IEC 81346-2":"Q","Max. rated operational voltage Ue with DC":"500 V","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / li max.":"320 A","Adjustable response value current / li min.":"320 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"S","Max. rated operational current of the frame size":"160 A","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=365769&mlfb=3VA1196-4ED36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1196-4ED36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What are the interrupting ratings for 3VA1196-4ED36-0AA0?","answer":"121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V."},{"question":"What is the continuous current rating and how does it derate with temperature?","answer":"Rated 16 A continuous (Iu) up to 55 °C, then derates to 15 A from 60 °C through 70 °C."},{"question":"Where can I buy 3VA1196-4ED36-0AA0?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1196-4ED36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1196-4ED36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}