{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1196-5EF32-0BH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1196-5EF32-0BH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1196-5EF32-0BH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1196-5EF32-0BH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 160, breaking capacity class M, 3-pole, line protection TM240, In=16A, Icu=55kA @ 415V, with undervoltage release 24V DC, 2 auxiliary switches HQ, 1 trip alarm switch HQ, nut keeper kit.","salesMarkdown":"The Siemens 3VA1196-5EF32-0BH0 is a 3-pole IEC frame 160 circuit breaker in the 3VA1 series, rated for breaking capacity class M with Icu=55kA at 415V. It carries a TM240 thermal-magnetic trip unit set at In=16A, with overload protection adjustable Ir=11A...16A and short-circuit protection Ii=10...20 x In. For a 160A frame with a 16A TM240 trip, this is a high-interrupting variant (class M) suited for installations with high available fault current, such as industrial switchboards or transformer secondaries. The adjustable Ir (11-16A) lets you fine-tune the overload threshold to match the protected conductor or load without swapping the trip unit. The Ii range of 10-20x In means the magnetic instantaneous trip can be set between 160A and 320A, giving selectivity headroom downstream. ## Deployment context The UVR at 24V DC provides undervoltage release — if the control voltage drops, the breaker trips, which is typical for emergency-stop circuits or safety disconnects where loss of control power must open the main feeder.","metaTitle":"Siemens 3VA1196-5EF32-0BH0 Circuit Breaker, 55kA @ 415V","metaDescription":"Siemens 3VA1196-5EF32-0BH0 IEC frame 160 circuit breaker, 55kA breaking capacity, 16A TM240, UVR 24V DC, 2 aux switches. Current production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=151502&mlfb=3VA1196-5EF32-0BH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1196-5EF32-0BH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1196-5EF32-0BH0 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing."},{"question":"What is the breaking capacity of this breaker?","answer":"The ultimate short-circuit breaking capacity Icu is 55kA at 415V, which is class M for the 3VA1 IEC frame 160 series."},{"question":"What accessories are included with 3VA1196-5EF32-0BH0?","answer":"It includes a nut keeper kit, an undervoltage release (UVR) at 24V DC, two auxiliary switches HQ, and one trip alarm switch HQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1196-5EF32-0BH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1196-5EF32-0BH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}