{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1225-6GF42-0HH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1225-6GF42-0HH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1225-6GF42-0HH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1225-6GF42-0HH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON molded case circuit breaker, 3VA1225-6GF42-0HH0, 250 A, 4-pole, line protection, breaking capacities 220 kA at 240 V, 154 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, 17 kA at 690 V.","salesMarkdown":"## Siemens 3VA1225-6GF42-0HH0 — 250 A SENTRON MCCB, 4-Pole, Line Protection Breaking capacity hits 220 kA at 240 V, 154 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V — that covers fault-current duty from low-voltage service entrances up to 690 V motor control centers without cascading upstream. ## Thermal Derating and Power Loss Rated 250 A from 40 °C through 50 °C ambient; above that it derates in 5 °C steps: 243 A at 55 °C, 237 A at 60 °C, 230 A at 65 °C, and 223 A at 70 °C. Maximum power loss is 57 W — that matters for enclosure heat rise calculations when the panel is fully populated. ## Auxiliary and Release Configuration No undervoltage release fitted from the factory. No ground-fault monitoring version. Footprint: 140 mm wide × 158 mm high × 70 mm deep. Four-pole width at 140 mm is standard for this frame size; check adjacent device spacing for heat dissipation.","metaTitle":"Siemens 3VA1225-6GF42-0HH0 SENTRON MCCB, 250 A, 4-Pole, 220","metaDescription":"Siemens 3VA1225-6GF42-0HH0 SENTRON molded case circuit breaker, 250 A, 4-pole, breaking capacity 220 kA at 240 V. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"140 mm","Height":"158 mm","Maximum":"250 A","Minimum":"250 A","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"75.6 kA","at 500 V":"30 kA","at 690 V":"17 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"243 A","at 60 °C":"237 A","at 65 °C":"230 A","at 70 °C":"223 A","Depth [In]":"2.76 in","Width [In]":"5.51 in","Height [In]":"6.22 in","Trip Indicator":"Yes","Number Of Poles":"4","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"57 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA12256GF420AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM240","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","design of the N-conductor protection":"100%","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"600 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bcc549f784677ecf8e72aaef8503ad9c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=568875&mlfb=3VA1225-6GF42-0HH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1225-6GF42-0HH0/alternatives.json"},"ai":{"faq":[{"question":"What are the breaking capacity ratings for 3VA1225-6GF42-0HH0 at different voltages?","answer":"Breaking capacity is 220 kA at 240 V, 154 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V."},{"question":"What is the width and depth of 3VA1225-6GF42-0HH0?","answer":"Width is 140 mm, depth is 70 mm, height is 158 mm."},{"question":"How do I get current pricing and availability for 3VA1225-6GF42-0HH0?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1225-6GF42-0HH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1225-6GF42-0HH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}