{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1510-5EF32-0CL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1510-5EF32-0CL0","canonicalUrl":"https://aoctrl.com/siemens/3VA1510-5EF32-0CL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1510-5EF32-0CL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1510-5EF32-0CL0, molded case circuit breaker, 3-pole, 1000 A at 40 °C, 187 kA breaking capacity at 240 V, line protection design, undervoltage release, 2 aux switches + trip alarm + electrical alarm.","salesMarkdown":"Its 187 kA breaking capacity at 240 V drops to 121 kA at 415 V and 440 V, then to 75.6 kA at 500 V and 52.5 kA at 690 V — so the interrupting duty you need at your system voltage is the one that governs the spec. ## Thermal derating — the real continuous current at your ambient Above that, it derates: 960 A at 55 °C, 940 A at 60 °C, 920 A at 65 °C, and 900 A at 70 °C. The maximum power loss of 332.5 W at rated current tells you the heat the breaker dumps into the enclosure; factor that into your thermal budget. ## Auxiliary configuration and release No ground-fault monitoring or communication function is fitted on this variant. Dimensions: 320 mm height, 210 mm width, 120 mm depth. The 210 mm width is the critical panel cutout dimension — verify against your existing MCCB footprint.","metaTitle":"Siemens 3VA1510-5EF32-0CL0 SENTRON MCCB, 1000 A, 3-Pole, 187","metaDescription":"Siemens 3VA1510-5EF32-0CL0 SENTRON molded case circuit breaker, 1000 A continuous at 40°C, 3-pole, 187 kA breaking at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"120 mm","Width":"210 mm","Height":"320 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"52.5 kA","at 40 °C":"1 000 A","at 45 °C":"1 000 A","at 50 °C":"1 000 A","at 55 °C":"960 A","at 60 °C":"940 A","at 65 °C":"920 A","at 70 °C":"900 A","Depth [In]":"4.72 in","Width [In]":"8.27 in","Height [In]":"12.6 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"332.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA15105EF320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM240","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB24","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"750 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"10 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=645666&mlfb=3VA1510-5EF32-0CL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1510-5EF32-0CL0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA1510-5EF32-0CL0 at 415 V?","answer":"121 kA at 415 V, same as at 440 V. At 500 V it drops to 75.6 kA, and at 690 V to 52.5 kA."},{"question":"What auxiliary switches come with this MCCB?","answer":"Two auxiliary switches, one trip alarm switch, and one electrical alarm switch (HQ configuration), plus an undervoltage release."},{"question":"How do I get pricing and availability for 3VA1510-5EF32-0CL0?","answer":"Submit an RFQ through this listing. The part is sourced to order; current pricing and stock status are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1510-5EF32-0CL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1510-5EF32-0CL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}