{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5HL32-0CL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5HL32-0CL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5HL32-0CL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL32-0CL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-5HL32-0CL0, molded case circuit breaker, 3-pole, 100 A continuous, 187 kA interrupting at 240 V, line protection design.","salesMarkdown":"## Built-in releases and auxiliaries That HQ-style alarm switch gives a dedicated signal for remote fault annunciation — useful when the MCCB is buried in a panel and you need a hardwired trip indication back to the PLC. The UVR drops the breaker on loss of control voltage, standard for emergency-stop or undervoltage protection schemes. ## Panel fit That 86 mm depth keeps the breaker within standard 200 mm enclosure depths — no need to step up to a deeper can for this frame size.","metaTitle":"Siemens 3VA2010-5HL32-0CL0 SENTRON MCCB, 100 A, 3-Pole, 187","metaDescription":"Siemens 3VA2010-5HL32-0CL0 SENTRON molded case circuit breaker, 100 A continuous, 3-pole, 187 kA at 240 V. Current lifecycle. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"16 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20105HL320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB24","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=104482&mlfb=3VA2010-5HL32-0CL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL32-0CL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-5HL32-0CL0 and get a price?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity and target delivery window."},{"question":"What is the interrupting capacity of 3VA2010-5HL32-0CL0 at 415 V?","answer":"121 kA at 415 V. That is the same rating as at 440 V, so the breaker handles the full IEC 60947-2 fault level for most 400 V-class industrial feeds without stepping up to a larger frame."},{"question":"Will 3VA2010-5HL32-0CL0 drop into a panel specified around 3VA1110-5EF32-0AM0?","answer":"No — the 3VA1110 series uses a different frame size and mounting footprint. The 3VA2010 is a physically larger breaker (181 x 105 x 86 mm vs the 3VA1110's compact frame). Panel cutouts, busbar spacing, and terminal positions differ. Rewiring and re-punching the backplate would be required."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5HL32-0CL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5HL32-0CL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}