{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5HL32-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5HL32-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5HL32-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL32-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-5HL32-0DL0, molded case circuit breaker, 3-pole, 100 A continuous, interrupting capacity 187 kA at 240 VAC, 121 kA at 415/440 VAC.","salesMarkdown":"The 3-pole construction and interrupting capacity of 187 kA at 240 VAC (121 kA at 415/440 VAC, 75.6 kA at 500 VAC, 3 kA at 690 VAC) mean it can clear high-fault currents on industrial feeders without upstream coordination issues. ## Built-in undervoltage release and auxiliary switching The auxiliary switch configuration includes two auxiliary switches, one trip alarm switch, and one electrical alarm switch (HQ type), giving the control system status feedback on breaker position and fault events. The 86 mm depth (3.39 in) leaves clearance for rear-access wiring in a typical distribution panel. Mounting is via the SENTRON base plate or DIN rail adapter; the 3-pole body fits the same cutout as other 3VA frame sizes.","metaTitle":"Siemens 3VA2010-5HL32-0DL0 SENTRON MCCB, 100 A, 3-Pole, 187","metaDescription":"Siemens SENTRON 3VA2010-5HL32-0DL0 molded case circuit breaker, 100 A continuous, 3-pole, interrupting up to 187 kA at 240 VAC. Active lifecycle. Sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"16 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20105HL320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=397715&mlfb=3VA2010-5HL32-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL32-0DL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-5HL32-0DL0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Contact us with your quantity and target price; availability and current pricing are confirmed at quote time."},{"question":"What is the interrupting capacity of this MCCB at 240 V?","answer":"At 240 VAC the interrupting capacity is 187 kA. At 415/440 VAC it is 121 kA, at 500 VAC it is 75.6 kA, and at 690 VAC it is 3 kA."},{"question":"Does this breaker include an undervoltage release?","answer":"Yes, the design of the auxiliary release is an undervoltage release (UVR), so the breaker trips on loss of control voltage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5HL32-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5HL32-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}