{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5HL32-0HL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5HL32-0HL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5HL32-0HL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL32-0HL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-5HL32-0HL0, molded case circuit breaker, 3-pole, 100 A rated continuous current, interrupting rating 187 kA at 240 V, line protection, ETU320 release.","salesMarkdown":"The Siemens SENTRON 3VA2010-5HL32-0HL0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current Iu of 100 A and a rated insulation voltage Ui of 800 V. Its interrupting capacity peaks at 187 kA at 240 V and holds at 121 kA across 415 V and 440 V — figures that tell you it can handle high-fault panels without cascading upstream. At 690 V the rating drops to 3.4 kA, so verify the available fault current at that voltage before committing the BOM line. The breaker carries an ETU320 electronic trip unit, a shunt trip (STL) auxiliary release, and a complement of auxiliary contacts: 2 auxiliary switches plus 1 trip alarm switch plus 1 electrical alarm switch (HQ version). ## Thermal derating and endurance Rated current holds at 100 A from 40 °C through 50 °C ambient. Above that it steps down: 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. Mechanical endurance is 20 000 cycles, which is typical for a distribution MCCB; not a switching-duty contactor, but fine for infrequent manual isolation. Dimensions: 105 mm wide, 181 mm high, 86 mm deep. That width is the standard 3-pole MCCB footprint for the SENTRON 3VA platform — it drops into the same panel cutout as other 100 A frames in the family. The depth of 86 mm means it clears a 100 mm deep enclosure without forcing a deeper gland plate. Operating temperature range is -25 °C to 70 °C; storage range -40 °C to 80 °C.","metaTitle":"Siemens 3VA2010-5HL32-0HL0 SENTRON MCCB, 100 A, 187 kA at 24","metaDescription":"Siemens SENTRON 3VA2010-5HL32-0HL0 molded case circuit breaker, 3-pole, 100 A, interrupting rating 187 kA at 240 V. Line protection with ETU320 release. Current production. Quoted","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"3.4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"13.5 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-5HL32-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL30","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"4","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=56147&mlfb=3VA2010-5HL32-0HL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL32-0HL0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting rating of 3VA2010-5HL32-0HL0 at 415 V?","answer":"121 kA at 415 V. The same rating applies at 440 V. At 240 V it reaches 187 kA; at 500 V it drops to 79 kA; at 690 V it is 3.4 kA."},{"question":"Where can I buy 3VA2010-5HL32-0HL0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What trip unit does 3VA2010-5HL32-0HL0 use?","answer":"ETU320 electronic trip unit. It is a line-protection release with no ground-fault monitoring, no phase-failure detection, and no communication function."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5HL32-0HL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5HL32-0HL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}