{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5HL36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5HL36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2010-5HL36-0AA0, 3-pole, 100 A continuous, ETU320 electronic trip unit, 187 kA interrupting at 240 V AC.","salesMarkdown":"The Siemens 3VA2010-5HL36-0AA0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. That 100 A is the rated current, not a maximum; the breaker's frame can handle up to 1 200 A, so this is a 100 A trip unit in a frame sized for future uprating if the load grows. Three-pole construction with an ETU320 electronic overcurrent release, designed for line protection (not motor or feeder). The interrupting ratings are what make this part stand out: 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. Insulation voltage rated 800 V, IP40 protection on the front (finger-safe against tools, not washdown). Many breakers derate above 40 °C; this one doesn't, so it's a good fit for hot environments like enclosed switchgear or outdoor panels in direct sun. The ETU320 electronic trip unit offers adjustable thermal and magnetic settings (not fixed), which gives selectivity flexibility downstream. Mounts in a standard MCCB panel cutout — no DIN rail. The 105 mm width means it occupies three pole spaces in a typical panel layout. Front IP40 protection is sufficient for enclosed panels; if the breaker is mounted on a door or exposed, consider a higher IP rated cover or enclosure. If you need remote tripping or status feedback, you'll need the accessory kit or a different order code. The ETU320 is a standalone electronic trip unit; it doesn't talk to a bus.","metaTitle":"Siemens 3VA2010-5HL36-0AA0 SENTRON MCCB, 100 A, 3-Pole, ETU3","metaDescription":"Siemens 3VA2010-5HL36-0AA0 SENTRON molded case circuit breaker, 100 A continuous, 3-pole, ETU320 release, 187 kA at 240 V. Active production, sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cdb0e9ba292545c88b4786a6c06b91d2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=190704&mlfb=3VA2010-5HL36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0AA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5HL36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}