{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5HL36-0AH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5HL36-0AH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0AH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0AH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2010-5HL36-0AH0, 100 A, 3-pole, line protection, 187 kA at 240 V, 121 kA at 415 V.","salesMarkdown":"The Siemens 3VA2010-5HL36-0AH0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. It is a 3-pole line-protection device, meaning it sits at the feeder or main distribution point in a panel, not on a motor branch. The 3VA2010-5HL36-0AH0 delivers 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. That steep drop at 690 V is typical for a 100 A frame — the arc energy at that voltage limits the interruption capability. The 3 kA at 690 V is enough for most 690 V motor control centers, but not for high-fault 690 V utility ties. ## Auxiliary switch configuration and trip indication A trip indicator is present on the front face — useful for remote status monitoring via the alarm contact. ## Environmental limits and power loss Maximum power loss is 13.5 W at rated current — a modest figure that keeps enclosure heat rise manageable in a standard panel.","metaTitle":"Siemens 3VA2010-5HL36-0AH0 SENTRON MCCB, 100 A, 3-Pole, 187","metaDescription":"Siemens 3VA2010-5HL36-0AH0 SENTRON molded case circuit breaker, 100 A continuous, 3-pole, 187 kA breaking at 240 V. Active production. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20105HL360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=396683&mlfb=3VA2010-5HL36-0AH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0AH0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this MCCB at 480 V?","answer":"The closest published rating is 121 kA at 440 V; at 480 V the value will be slightly lower but still in the same range. For exact coordination, consult the selective coordination tables in the SENTRON 3VA2 manual."},{"question":"Where can I buy 3VA2010-5HL36-0AH0 and how is it quoted?","answer":"This part is sourced to order through independent distribution channels. Submit an RFQ for current pricing and availability — both are confirmed at quote time, not before."},{"question":"Does this breaker include a shunt trip or undervoltage release?","answer":"No. This variant (5HL36 in the order code) has no undervoltage release and no voltage trigger. It ships with 2 auxiliary switches and 1 trip alarm switch only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0AH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5HL36-0AH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}