{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5HL36-0BE0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5HL36-0BE0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0BE0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0BE0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-5HL36-0BE0, molded case circuit breaker, 3-pole, 100 A continuous, 187 kA at 240 V, line protection with undervoltage release.","salesMarkdown":"That 100 A holds steady at every 5 °C increment, so it's sized for a 100 A feeder or a 100 A motor branch circuit without having to oversize for a hot panel. Three-pole design, line-protection configuration, and an integrated undervoltage release (UVR) that drops the breaker if control voltage is lost — common in safety circuits where a loss of 24 VDC or 120 VAC control power needs to kill the load. The interrupting ratings climb with system voltage: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. The 100 A frame carries a minimum trip setting of 150 A and a maximum of 1 200 A — that's the magnetic (instantaneous) pickup range, not the continuous rating. For a 100 A feeder, the thermal element is fixed at 100 A; the magnetic adjustment lets you coordinate with downstream breakers or motor starters without changing the frame. That 105 mm width is the standard 3-pole MCCB footprint for the 3VA frame — it fits the same panel cutout and bus-bar spacing as other 3VA 100 A units. The auxiliary switch block is pre-configured with four HQ auxiliary switches (form C contacts). That's enough for remote status indication (open/closed/tripped) plus a spare pair for a PLC input or a panel lamp. The undervoltage release is a separate coil module that mounts on the left side of the breaker; it's wired in series with the control transformer or safety relay output.","metaTitle":"Siemens 3VA2010-5HL36-0BE0 SENTRON MCCB, 100 A, 3-Pole, 187","metaDescription":"Siemens SENTRON 3VA2010-5HL36-0BE0 molded case circuit breaker, 100 A continuous, 3-pole, 187 kA at 240 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"16 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20105HL360AA0","Design Of The Auxiliary Switch":"4 auxiliary switches HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB11","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=675837&mlfb=3VA2010-5HL36-0BE0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0BE0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-5HL36-0BE0 and how do I get a price?","answer":"Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is 3VA2010-5HL36-0BE0's listed depth?","answer":"86 mm (3.39 in). That's the overall depth including the arc chamber and terminals — enough for most standard-depth enclosures, but verify cable bending clearance behind the breaker."},{"question":"What compliance documentation does this brand provide for 3VA2010-5HL36-0BE0?","answer":"As a Siemens SENTRON MCCB, it carries UL, CSA, and IEC certifications standard for the 3VA platform. RoHS and REACH declarations are available through Siemens documentation channels."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0BE0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5HL36-0BE0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}