{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5HL36-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5HL36-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA series, molded case circuit breaker, 3VA2010-5HL36-0DL0, 100 A continuous, 3-pole, line protection, 187 kA at 240 V.","salesMarkdown":"## MCCB for line protection with UVR and full aux switch set It is a 3-pole unit designed specifically for line protection — feeder or main breaker duty in a distribution panel, not motor protection. Breaking capacity scales from 187 kA at 240 V down to 3 kA at 690 V, which gives selectivity headroom at common low-voltage levels while still clearing faults on 690 V systems. The factory-fit auxiliary switch complement includes two auxiliary switches, one trip alarm switch, and one electrical alarm switch, plus an undervoltage release (UVR) — a complete signalling and shunt-trip package that eliminates field-fitting loose accessories. The breaker measures 105 mm wide, 181 mm high, and 86 mm deep — a compact 3-pole footprint that fits standard SENTRON 3VA panel cutouts and busbar centres. ## Thermal and environmental limits Maximum power loss is 16 W at rated load — a useful figure for panel heat-budget calculations. The breaker includes a trip indicator for visual fault confirmation.","metaTitle":"Siemens 3VA2010-5HL36-0DL0 SENTRON MCCB, 100 A, 3-Pole","metaDescription":"Siemens SENTRON 3VA2010-5HL36-0DL0 molded case circuit breaker, 100 A continuous, 3-pole, line protection. Breaking capacity 187 kA at 240 V. Undervoltage release. Current lifecycl","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"16 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20105HL360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=418118&mlfb=3VA2010-5HL36-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0DL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-5HL36-0DL0?","answer":"This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time, not from a shelf count."},{"question":"What is the breaking capacity of 3VA2010-5HL36-0DL0 at different voltages?","answer":"Breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. The 187 kA at 240 V gives strong SCCR headroom for 240 V delta or 277/480 V wye systems with high fault current."},{"question":"Does 3VA2010-5HL36-0DL0 include an undervoltage release?","answer":"Yes, it ships with an undervoltage release (UVR) fitted, plus two auxiliary switches, one trip alarm switch, and one electrical alarm switch — a complete accessory set for signalling and shunt-trip applications."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5HL36-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}