{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5HL36-0JC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5HL36-0JC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0JC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0JC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-5HL36-0JC0, molded case circuit breaker (MCCB), line protection, 3-pole, 100 A continuous, interrupting 187 kA at 240 V AC, with shunt trip release and 2 auxiliary switches HQ.","salesMarkdown":"Interrupting capacity is the headline here: 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. That simplifies panel design: no need to upsize the frame for a 60 °C enclosure interior. That storage range covers unheated warehouses in cold climates — the breaker can sit on a shelf at -40 °C without damage, provided it's warmed above -25 °C before energizing. Depth of 86 mm means it clears a 120 mm deep enclosure without crowding the gland plate. The basic switch variant is 3VA20105HL360AA0, which confirms the internal mechanism. The auxiliary switch design carries two HQ auxiliary switches — these are high-quantity (HQ) form-C contacts for status signaling to a PLC or SCADA.","metaTitle":"Siemens 3VA2010-5HL36-0JC0 SENTRON MCCB, 100 A, 3-Pole, 187","metaDescription":"Siemens SENTRON 3VA2010-5HL36-0JC0 molded case circuit breaker, 100 A continuous, 3-pole, 187 kA interrupting at 240 V. Active lifecycle, sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20105HL360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=341034&mlfb=3VA2010-5HL36-0JC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0JC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-5HL36-0JC0 and how is it quoted?","answer":"This MCCB is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock figures are published here."},{"question":"What is the interrupting capacity of this breaker at 240 V?","answer":"187 kA at 240 V AC, which is high for a 100 A frame — suitable for installation close to a large transformer without requiring current-limiting fuses upstream."},{"question":"Does this breaker include a shunt trip?","answer":"Yes, the auxiliary release design includes a shunt trip (STL), allowing remote tripping from a pushbutton or safety relay."},{"question":"Will 3VA2010-5HL36-0JC0 drop into a panel designed for 3VA1110-5ED36-0AC0?","answer":"Both are 3-pole SENTRON MCCBs in similar frame sizes, but the 3VA1110 series is a different product generation with different accessory slot layout. Physical dimensions may differ — verify cutout and busbar spacing against the panel drawing before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0JC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5HL36-0JC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}