{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5HL36-0KA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5HL36-0KA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0KA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0KA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-5HL36-0KA0, 3-pole molded case circuit breaker, 100 A rated continuous current Iu, ETU320 electronic trip unit, 187 kA breaking capacity at 240 V, shunt trip STL, line protection version.","salesMarkdown":"The Siemens 3VA2010-5HL36-0KA0 is a 3-pole molded case circuit breaker from the SENTRON 3VA series, rated for line protection at 100 A continuous current (Iu) with an ETU320 electronic trip unit. It delivers 187 kA breaking capacity at 240 V AC — that figure drops to 121 kA at 415 V and 440 V, 79 kA at 500 V, and 3.4 kA at 690 V, so the voltage class of your distribution determines whether this breaker clears a fault without cascading upstream. Above that, it steps down: 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. The shunt trip (STL) release (order code 3VA9688-0BL33) is built in, so you can remotely trip the breaker from an emergency-stop circuit or a PLC output without adding external undervoltage gear. No auxiliary contacts are included — those are ordered separately if you need status feedback.","metaTitle":"Siemens 3VA2010-5HL36-0KA0 MCCB, 100 A, 187 kA at 240 V","metaDescription":"Siemens SENTRON 3VA2010-5HL36-0KA0 molded case circuit breaker, 3-pole, 100 A rated continuous current, 187 kA breaking at 240 V, ETU320 release, shunt trip. Active production, sou","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"3.4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"13.5 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-5HL36-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL33","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=307223&mlfb=3VA2010-5HL36-0KA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0KA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-5HL36-0KA0?","answer":"It is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of this MCCB?","answer":"187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 3.4 kA at 690 V."},{"question":"Does this breaker include a shunt trip?","answer":"Yes, it is equipped with a shunt trip (STL) release — order code 3VA9688-0BL33 for the integrated auxiliary trip unit."},{"question":"What compliance documentation is available for this part?","answer":"As a Siemens SENTRON MCCB, it ships with IEC 60947-2 and UL 489 certifications; RoHS and REACH declarations are standard. Specific certificates are provided with the order documentation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0KA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5HL36-0KA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}