{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5HL36-0KL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5HL36-0KL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0KL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0KL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-5HL36-0KL0, molded case circuit breaker, 3-pole, 100 A, 187 kA at 240 V, ETU320 release, shunt trip, line protection.","salesMarkdown":"The Siemens SENTRON 3VA2010-5HL36-0KL0 is a 3-pole molded case circuit breaker rated for 100 A continuous current, with an interrupting capacity of 187 kA at 240 V and 121 kA at 415 V. Those numbers mean it can clear a bolted fault on a large transformer secondary or a high-capacity bus without the arc re-striking — the kind of SCCR headroom you need for a main breaker in a 480 V industrial panel. A shunt trip (STL) is built in for remote emergency-off or fire-alarm cut. At 55 °C it derates to 96.25 A, at 60 °C to 92.5 A, at 65 °C to 88.75 A, and at 70 °C to 85 A. ## Auxiliary contacts and alarm switching This variant ships with two auxiliary switches, one trip alarm switch, and one electrical alarm switch (HQ type). That gives you a dedicated signal for remote status — breaker open/closed, trip event, and a separate alarm contact for SCADA or a local beacon. If you need UVR or ground-fault monitoring, you are looking at a different suffix. That width is standard for a 3-pole 100 A frame in the 3VA platform — it fits the same mounting footprint as other 3VA100/160 frame breakers. The depth of 86 mm includes the handle and the shunt trip projection; allow clearance for wiring and the auxiliary contact block on the side.","metaTitle":"Siemens 3VA2010-5HL36-0KL0 SENTRON MCCB, 100 A, 3-pole, 187","metaDescription":"Siemens SENTRON 3VA2010-5HL36-0KL0 molded case circuit breaker, 100 A, 3-pole, 187 kA at 240 V. ETU320 release, shunt trip. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"3.4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"13.5 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-5HL36-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL33","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"4","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=262882&mlfb=3VA2010-5HL36-0KL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HL36-0KL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-5HL36-0KL0 and get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a quote request for current availability and pricing — confirmed at quote time."},{"question":"What is the interrupting capacity of 3VA2010-5HL36-0KL0 at 415 V?","answer":"The interrupting capacity is 121 kA at 415 V, and the same at 440 V. At 240 V it reaches 187 kA."},{"question":"What trip unit does this MCCB use?","answer":"It uses the ETU320 electronic trip unit, which provides adjustable long-time, short-time, and instantaneous protection. The release is a shunt trip (STL)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5HL36-0KL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5HL36-0KL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}