{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5HN36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5HN36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5HN36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HN36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-5HN36-0AA0, molded case circuit breaker, 3-pole, 100 A continuous, interrupting 187 kA at 240 V, ETU350 release, line protection.","salesMarkdown":"The Siemens SENTRON 3VA2010-5HN36-0AA0 is a 3-pole molded case circuit breaker rated for 100 A continuous current at 40 °C, with the same rating holding flat through 70 °C — no derating needed across the full operating temperature band. Its ETU350 electronic overcurrent release provides adjustable trip curves for line protection duty. This MCCB delivers 187 kA interrupting capacity at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. Dimensions: 181 mm height, 105 mm width, 86 mm depth. Front IP40 protection covers the operator interface against tool entry and small debris. ## Environmental and power loss Maximum power dissipation is 13.5 W at rated load — relevant for enclosure thermal budgeting, especially in sealed or high-density panels.","metaTitle":"Siemens 3VA2010-5HN36-0AA0 SENTRON MCCB, 100 A, 3-Pole, 187","metaDescription":"Siemens SENTRON 3VA2010-5HN36-0AA0 molded case circuit breaker, 100 A continuous, 3-pole, 187 kA interrupting at 240 V. Current lifecycle. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"1 200 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/12982900e1b300fcebe1eada4745f948.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=392746&mlfb=3VA2010-5HN36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5HN36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-5HN36-0AA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings of 3VA2010-5HN36-0AA0?","answer":"Continuous current 100 A, 3-pole, interrupting 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 500 V, 3 kA at 690 V. Insulation voltage 800 V. ETU350 electronic release for line protection."},{"question":"Will 3VA2010-5HN36-0AA0 drop into a panel specified around 3VA2116-5JP32-0AE0?","answer":"The 3VA2010-5HN36-0AA0 is a 100 A frame (3VA2), while the 3VA2116-5JP32-0AE0 is a 160 A frame (3VA2). Both share the same SENTRON 3VA2 platform width and depth, but the 100 A frame has a different height and busbar connection pattern — verify panel cutout dimensions and busbar spacing before substitution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5HN36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5HN36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}