{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5JQ32-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5JQ32-0AB0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5JQ32-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5JQ32-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-5JQ32-0AB0, molded case circuit breaker, 3-pole, 100 A, 187 kA at 240 V, depth 86 mm.","salesMarkdown":"## What this MCCB does on the line The Siemens SENTRON 3VA2010-5JQ32-0AB0 is a 3-pole molded case circuit breaker rated for line protection, carrying a full-scale value of 100 A across the entire ambient range from 40 °C to 70 °C — no derating curve to chase when the panel gets hot. With a breaking capacity of 187 kA at 240 V and 121 kA at 415 V, it handles high-fault utility feeds without cascading upstream — sized for main or large feeder duty in industrial switchboards. The 86 mm depth and 105 mm width fit standard SENTRON mounting patterns, so a panel builder can swap this into an existing 3VA lineup without redrilling the gland plate. ## Panel fit and field notes Dimensions are 86 mm deep by 105 mm wide by 181 mm tall — a 3-pole MCCB footprint that drops into a SENTRON panelboard or standalone enclosure without surprises. Maximum power loss is 13.5 W, which keeps internal cabinet temperature rise manageable even in a densely packed lineup. Operating temperature range of -25 °C to 70 °C and storage range of -40 °C to 80 °C cover most unheated plant floors and warehouse conditions.","metaTitle":"Siemens 3VA2010-5JQ32-0AB0 SENTRON MCCB, 100 A, 3-Pole, 86 m","metaDescription":"Siemens SENTRON 3VA2010-5JQ32-0AB0 molded case circuit breaker, 100 A rated at 40-70°C, 3-pole, 187 kA at 240 V. Current production. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Initial Value":"20 A","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Full-Scale Value":"100 A","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20105JQ320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HP","Ground-Fault Monitoring Version":"Summation current formation L-conductor","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU560","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Product Function / Grounding Protection":"Yes","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSIG","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA11","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=324127&mlfb=3VA2010-5JQ32-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5JQ32-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this brand provide for 3VA2010-5JQ32-0AB0?","answer":"As a SENTRON molded case circuit breaker, it is designed and tested to IEC and UL standards for line protection; specific RoHS/REACH declarations are available from the manufacturer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5JQ32-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5JQ32-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}