{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5JQ32-0CL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5JQ32-0CL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5JQ32-0CL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5JQ32-0CL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA series, molded case circuit breaker (MCCB), 3VA2010-5JQ32-0CL0, 100 A, 3-pole, ETU560 electronic trip unit, line protection.","salesMarkdown":"It's a current-production part (lifecycle stage: current) from the 3VA platform, meaning it's the active design you'd spec into a new panel or pull as a like-for-like replacement on an existing SENTRON line. This MCCB delivers 187 kA interrupting capacity at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 3.4 kA at 690 V. For most 400 V-class industrial panels, the 121 kA rating gives solid selectivity headroom against upstream 1600 A or 2000 A frames. Above that, it derates: 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. It also includes an undervoltage release (UVR) — the design of the auxiliary release is listed as undervoltage release. That UVR is useful for safety circuits where a loss of control voltage should drop the breaker open, or for remote shunt-trip applications. The HQ auxiliary contact block gives you enough dry contacts for a PLC status input, a remote SCADA alarm, and a local panel light, with one spare. ## Communication capability A communication function is present on this unit. The 3VA platform supports plug-in communication modules (PROFIBUS, PROFINET, Modbus TCP) via the 3VA9 accessory range. If you need to pull trip data, energy metering, or breaker status into a control system, this frame accepts those modules. The base breaker without a module installed still communicates via the mechanical flag and auxiliary contacts, but the electronic trip's data port is ready for a module. The 105 mm width is standard for a 3-pole 100 A frame in the 3VA series — it fits the same mounting footprint as other 3VA1 3-pole units. The 86 mm depth includes the handle and arc-chamber protrusion; check clearance to the enclosure door if you're mounting it in a shallow wall-mount box. Panel cutout and mounting pattern match the 3VA1 family, so a swap from an older 3VA1 or 3VL frame may need a new escutcheon or adapter plate.","metaTitle":"Siemens 3VA2010-5JQ32-0CL0 SENTRON MCCB, 100 A, 3-Pole, ETU5","metaDescription":"Siemens SENTRON 3VA2010-5JQ32-0CL0 molded case circuit breaker, 100 A rated continuous current, 3-pole, ETU560 electronic trip unit. Breaking capacity 187 kA at 240 V. Current prod","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"3.4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"16 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-5JQ32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Summation current formation L-conductor","Of The Integrated Auxiliary Trip":"3VA9608-0BB24","Design of the overcurrent release":"ETU560","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"25","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / lg max.":"100 A","Adjustable response value current / lg min.":"20 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Adjustable response value current / Isd max.":"1 000 A","Adjustable response value current / Isd min.":"60 A","Ground fault protection can be switched ON/OFF":"Yes","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"4","Protective function of the overcurrent release":"LSIG","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=291995&mlfb=3VA2010-5JQ32-0CL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5JQ32-0CL0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2010-5JQ32-0CL0?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) and we will confirm availability and current pricing at quote time — no automated stock figures are published here."},{"question":"What is the breaking capacity of 3VA2010-5JQ32-0CL0 at 415 V?","answer":"It is rated 121 kA at 415 V, matching the 440 V rating. At 240 V it reaches 187 kA; at 500 V it drops to 79 kA; at 690 V it is 3.4 kA."},{"question":"What trip unit does 3VA2010-5JQ32-0CL0 use?","answer":"It uses the ETU560 electronic overcurrent release, which provides adjustable long-time, short-time, and instantaneous protection for line protection applications."},{"question":"What auxiliary contacts are included on this breaker?","answer":"It ships with 2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch (HQ configuration), plus an integrated undervoltage release (UVR)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5JQ32-0CL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5JQ32-0CL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}