{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5JQ32-0HH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5JQ32-0HH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5JQ32-0HH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5JQ32-0HH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-5JQ32-0HH0, molded case circuit breaker, 3-pole, 100 A, 187 kA at 240 V, ETU560 electronic trip, shunt trip, 2 aux + 1 alarm switch.","salesMarkdown":"## What this 100 A MCCB does on the line The Siemens 3VA2010-5JQ32-0HH0 is a 3-pole SENTRON molded case circuit breaker rated 100 A continuous at 40 °C, with an ETU560 electronic trip unit that handles line protection. At 415 V and 440 V it still holds 121 kA, and at 690 V it drops to 3.4 kA, so the voltage class of your distribution determines which SCCR column you read. The 100 A rating holds flat from 40 °C to 50 °C, then steps down: 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. Dimensions are 105 mm wide, 181 mm tall, 86 mm deep — standard SENTRON 3VA footprint for a 100 A frame, so it drops into the same DIN-rail or mounting-plate cutout as other 3VA100/200-series breakers.","metaTitle":"Siemens 3VA2010-5JQ32-0HH0 SENTRON MCCB, 100 A, 187 kA at 24","metaDescription":"Siemens 3VA2010-5JQ32-0HH0 SENTRON molded case circuit breaker, 100 A rated, 187 kA breaking at 240 V. ETU560 electronic trip. Current lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"3.4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"13.5 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-5JQ32-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Summation current formation L-conductor","Of The Integrated Auxiliary Trip":"3VA9688-0BL30","Design of the overcurrent release":"ETU560","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"25","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / lg max.":"100 A","Adjustable response value current / lg min.":"20 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Adjustable response value current / Isd max.":"1 000 A","Adjustable response value current / Isd min.":"60 A","Ground fault protection can be switched ON/OFF":"Yes","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LSIG","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=226921&mlfb=3VA2010-5JQ32-0HH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5JQ32-0HH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-5JQ32-0HH0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing."},{"question":"What is 3VA2010-5JQ32-0HH0's breaking capacity at 240 V?","answer":"The breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 3.4 kA at 690 V."},{"question":"What trip unit does this MCCB use?","answer":"It uses the ETU560 electronic trip unit, configured for line protection."},{"question":"What auxiliary contacts come with this breaker?","answer":"It ships with 2 auxiliary switches plus 1 trip alarm switch (HQ configuration), and includes a shunt trip (STL) auxiliary release."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5JQ32-0HH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5JQ32-0HH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}