{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5KP32-0CL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5KP32-0CL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5KP32-0CL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5KP32-0CL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON, Molded case circuit breaker, 3VA2010-5KP32-0CL0, 3-pole, 100 A, line protection, ETU850 electronic release, 187 kA at 240 V, undervoltage release, communication function.","salesMarkdown":"The Siemens 3VA2010-5KP32-0CL0 is a SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current at 40 °C through 50 °C, with a linear derating curve down to 85 A at 70 °C. That 100 A frame is the one you size the feeder for — the breaker holds that rating across the typical panel ambient range, so no headroom padding needed unless the enclosure runs above 50 °C. Breaking capacity is the headline number here: 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 3.4 kA at 690 V. At 415 V, that 121 kA rating puts it well above typical utility fault levels for most industrial services — you're not coordination-limited by the main breaker on a 2 MVA transformer secondary. The steep drop to 3.4 kA at 690 V means this is not a 690 V main; it's a 240–500 V distribution breaker. Communication function is integrated, so it can report status and trip events to a higher-level control system — useful for a plant-wide power monitoring scheme where you want to know which feeder cleared before the electrician walks the line. The undervoltage release (UVR) is factory-fitted as design of the auxiliary release, part number 3VA9608-0BB24. If your panel schematic calls for a shunt trip instead, this variant won't drop in without swapping the release module. Maximum power loss is 16 W at rated current.","metaTitle":"Siemens 3VA2010-5KP32-0CL0 SENTRON MCCB, 100 A, 3-Pole, 187","metaDescription":"Siemens 3VA2010-5KP32-0CL0 SENTRON molded case circuit breaker, 100 A rated, 3-pole, line protection, ETU850 release, 187 kA at 240 V. Current lifecycle stage, sourced to order. Re","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"3.4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"16 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-5KP32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB24","Design of the overcurrent release":"ETU850","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"25","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Adjustable response value current / Isd max.":"1 000 A","Adjustable response value current / Isd min.":"60 A","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"4","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=454758&mlfb=3VA2010-5KP32-0CL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5KP32-0CL0/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for 3VA2010-5KP32-0CL0?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time; the part is sourced to order through independent distribution channels."},{"question":"Will 3VA2010-5KP32-0CL0 drop into a panel specified around 3VA2010-5HL36-0BE0?","answer":"Yes, the footprint and mounting are identical — same 105 mm width, same 3-pole frame. The difference is the trip unit: this one has the ETU850 with communication and an integrated undervoltage release, while the 5HL36 variant lacks those. No rewiring needed for the power connections, but verify the control wiring for the UVR and comms module."},{"question":"What is the depth of 3VA2010-5KP32-0CL0?","answer":"86 mm. That's the body depth excluding the handle and terminal projections — enough clearance for rear-connected busbars or a cable duct behind the panel backplate."},{"question":"What compliance documentation is available for this MCCB?","answer":"As a Siemens SENTRON product, it carries the usual IEC/EN 60947-2 certification for molded case circuit breakers. RoHS and REACH declarations are available from Siemens on request. The specific approvals (UL, CSA, CCC) depend on the exact variant; verify with the order code against the Siemens certificate database."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5KP32-0CL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5KP32-0CL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}