{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-5KP32-0HL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-5KP32-0HL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-5KP32-0HL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5KP32-0HL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON, molded case circuit breaker, 3VA2010-5KP32-0HL0, 100 A, 3-pole, ETU850 electronic trip unit, 187 kA at 240 V.","salesMarkdown":"## SENTRON 3VA2010-5KP32-0HL0 — 100 A MCCB with ETU850, active production The ETU850 electronic trip unit provides adjustable protection curves and integrates a communication function for remote monitoring or integration into a higher-level energy management system. Breaking capacity is voltage-dependent: 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 3.4 kA at 690 V. This makes it suitable for high-fault-current installations at common distribution voltages, with the 690 V figure indicating a reduced but still serviceable interruption capability for that voltage class. The breaker carries a mechanical endurance of 20,000 operations. Derating begins at 55 °C (96.25 A), stepping down to 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. Maximum power loss is 13.5 W. Panel builders should account for this dissipation in enclosure thermal calculations, especially when grouping multiple breakers. Dimensions are 181 mm height, 105 mm width, 86 mm depth. ## Auxiliary components and wiring note The base switch internal subcomponent is 3VA2010-5KP32-0AA0; the integrated auxiliary trip subcomponent is 3VA9688-0BL30. No undervoltage release or phase failure detection is included on this variant. No ground fault monitoring version is fitted.","metaTitle":"Siemens 3VA2010-5KP32-0HL0 SENTRON MCCB, 100 A, 3-Pole, ETU8","metaDescription":"Siemens 3VA2010-5KP32-0HL0 SENTRON molded case circuit breaker, 100 A rated continuous current, 3-pole, ETU850 electronic trip unit, 187 kA at 240 V. Active production. Quoted to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"3.4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"13.5 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-5KP32-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL30","Design of the overcurrent release":"ETU850","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"25","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Adjustable response value current / Isd max.":"1 000 A","Adjustable response value current / Isd min.":"60 A","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"4","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=269266&mlfb=3VA2010-5KP32-0HL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-5KP32-0HL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-5KP32-0HL0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the breaking capacity of 3VA2010-5KP32-0HL0 at different voltages?","answer":"Breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 3.4 kA at 690 V."},{"question":"What is the rated continuous current and derating for 3VA2010-5KP32-0HL0?","answer":"Rated continuous current Iu is 100 A from 40 °C to 50 °C. Derating begins at 55 °C (96.25 A) and steps down to 85 A at 70 °C."},{"question":"What are the physical dimensions of 3VA2010-5KP32-0HL0?","answer":"Height is 181 mm, width is 105 mm, depth is 86 mm."},{"question":"What trip unit and auxiliary options does 3VA2010-5KP32-0HL0 include?","answer":"It uses an ETU850 electronic trip unit with communication function. It includes a shunt trip (STL) auxiliary release and an auxiliary contact block: 2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-5KP32-0HL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-5KP32-0HL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}