{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HL32-0AC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HL32-0AC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0AC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0AC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-6HL32-0AC0, molded case circuit breaker, 3-pole, 100 A, 242 kA at 240 V, ETU320 electronic trip unit, line protection.","salesMarkdown":"## Siemens 3VA2010-6HL32-0AC0 — 100 A MCCB with ETU320 Trip Unit The Siemens SENTRON 3VA2010-6HL32-0AC0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current at 40 °C, with a rated insulation voltage of 800 V. It carries a 242 kA breaking capacity at 240 V, dropping to 187 kA at 415 V and 440 V, and 121 kA at 500 V — at 690 V it still holds 4 kA. The electronic trip unit is an ETU320, a line-protection variant (no ground-fault or voltage-trip function). Current rating holds flat at 100 A from 40 °C up to 50 °C; above that it derates linearly to 85 A at 70 °C. Maximum power loss is 13.5 W, which is manageable for a standard steel enclosure with passive ventilation. That depth (86 mm) is shallow enough to fit most 200 mm deep enclosures without a gland-plate conflict.","metaTitle":"Siemens 3VA2010-6HL32-0AC0 SENTRON MCCB, 100 A, 242 kA at 24","metaDescription":"Siemens SENTRON 3VA2010-6HL32-0AC0 molded case circuit breaker, 3-pole, 100 A rated continuous current, 242 kA breaking capacity at 240 V. Active production, sourced to order. Requ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"13.5 W","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-6HL32-0AA0","Design of the auxiliary release":"Without auxiliary release","Ground fault monitoring version":"Without","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=200349&mlfb=3VA2010-6HL32-0AC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0AC0/alternatives.json"},"ai":{"faq":[{"question":"Will 3VA2010-6HL32-0AC0 drop into a panel specified around 3VA1010-2ED32-0JA0?","answer":"Both share the same 3VA mounting footprint and 3-pole width, so mechanical fit is identical. The electrical difference is the trip unit and breaking capacity — the 3VA2010 carries the ETU320 electronic trip and higher SCCR, so it can replace the 3VA1010 in most panels without rewiring, provided the higher fault rating doesn't create a coordination issue downstream."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0AC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HL32-0AC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}