{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HL32-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HL32-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-6HL32-0BA0, molded case circuit breaker, 3-pole, 100 A, line protection, ETU320, 242 kA at 240 V.","salesMarkdown":"The 3VA2010-6HL32-0BA0: The interrupting capacity is substantial: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4 kA at 690 V. This SCCR headroom means it can be applied in high-fault-capacity industrial panels without cascading upstream. This thermal curve is critical for panel builders calculating fill factor and heat rise inside the enclosure. Dimensions are 181 mm height, 105 mm width, and 86 mm depth. Maximum power loss is 16 W at rated current — a modest figure that simplifies thermal management in a sealed enclosure. ## Release and compliance The UVR ensures the breaker trips on loss of control voltage — a standard requirement for safety circuits and emergency-stop chains. The part carries no auxiliary contact version or communication function — it is a standalone line-protection device.","metaTitle":"Siemens 3VA2010-6HL32-0BA0 SENTRON MCCB, 100A, 242kA at 240V","metaDescription":"Siemens SENTRON 3VA2010-6HL32-0BA0 molded case circuit breaker, 100A rated continuous current, 3-pole, line protection, ETU320 release, 242 kA at 240 V. Active production. Quoted t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"16 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-6HL32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB11","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=410108&mlfb=3VA2010-6HL32-0BA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0BA0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting capacity of 3VA2010-6HL32-0BA0 at 415 V?","answer":"The interrupting capacity is 187 kA at 415 V, which is the same rating as at 440 V. At 240 V it reaches 242 kA, and at 690 V it is 4 kA."},{"question":"Where can I buy 3VA2010-6HL32-0BA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"Does 3VA2010-6HL32-0BA0 include an undervoltage release?","answer":"Yes, it is fitted with an undervoltage release (UVR) as the design of the auxiliary release. The UVR trips the breaker when control voltage drops below the dropout threshold."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HL32-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}