{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HL32-0BH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HL32-0BH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0BH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0BH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON molded case circuit breaker, 3VA2010-6HL32-0BH0, 3-pole, 100 A continuous, trip range 150–1200 A, with undervoltage release and auxiliary switches.","salesMarkdown":"The Siemens SENTRON 3VA2010-6HL32-0BH0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from -25 °C to 70 °C — no derating needed up to the 70 °C mark. That 100 A is the continuous current, not the trip setting; the thermal-magnetic trip unit is adjustable between 150 A and 1200 A, so this breaker covers feeder and main applications where the load current is 100 A but the short-circuit and overload protection must be set higher to coordinate with downstream devices. The interrupting ratings are the real headline: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V. At 690 V the rating drops sharply — this is a 600 V class breaker, not a 690 V main; use it on 480/600 V systems where the available fault current stays under 121 kA. That means you get remote status indication and undervoltage protection without adding separate accessories. The design is line protection (feeder / main), not motor protection; if you need a motor-circuit protector, look at the 3VA2 variants. The depth of 86 mm (3.39 in) is compact enough for shallow enclosures. No special cutout or adapter plate required for most distribution panels. The breaker includes a trip indicator (mechanical flag) for local fault indication.","metaTitle":"Siemens 3VA2010-6HL32-0BH0 SENTRON MCCB, 100 A, 3-Pole, 150–","metaDescription":"Siemens SENTRON 3VA2010-6HL32-0BH0 molded case circuit breaker, 100 A continuous, 3-pole, line protection with undervoltage release. SCCR 242 kA at 240 V. Active lifecycle. Sourced","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"16 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20106HL320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB11","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=34941&mlfb=3VA2010-6HL32-0BH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0BH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-6HL32-0BH0 and how do I get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm availability and current pricing — no stock count or price is listed here."},{"question":"What is 3VA2010-6HL32-0BH0's listed depth (86 mm) on this component line?","answer":"The depth is 86 mm (3.39 in). Width is 105 mm (4.13 in), height is 181 mm (7.13 in)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0BH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HL32-0BH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}