{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HL32-0CA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HL32-0CA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0CA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0CA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, Molded case circuit breaker, 3VA2010-6HL32-0CA0, 100 A, 3-pole, 242 kA at 240 V, Line protection, ETU320 release, Undervoltage release.","salesMarkdown":"The Siemens SENTRON 3VA2010-6HL32-0CA0 is a 3-pole molded case circuit breaker rated for 100 A continuous current at 40 °C, with an ETU320 electronic trip unit for line protection. At 415 V and 440 V it still holds 187 kA, dropping to 121 kA at 500 V and 4 kA at 690 V. The trip indicator is absent, and there is no voltage trigger. Mechanical endurance is rated at 20,000 operations. Maximum power loss is 16 W. Dimensions are 181 mm height, 105 mm width, and 86 mm depth — this width (105 mm) is what determines whether it fits a standard 3-pole MCCB slot in a panel without re-drilling the gland plate. At 55 °C it derates to 96.25 A, at 60 °C to 92.5 A, at 65 °C to 88.75 A, and at 70 °C to 85 A. That means in a hot panel — say a crowded enclosure near a furnace line — you lose 15 A off the top at max operating temp. Plan the load accordingly; don't assume 100 A at the panel's internal ambient.","metaTitle":"Siemens 3VA2010-6HL32-0CA0 SENTRON MCCB, 100A, 3-pole, 242kA","metaDescription":"Siemens SENTRON 3VA2010-6HL32-0CA0 molded case circuit breaker, 100A rated continuous current, 3-pole, 242kA breaking capacity at 240V. Active production, sourced to order. Quoted","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"16 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-6HL32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB24","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=36347&mlfb=3VA2010-6HL32-0CA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0CA0/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3VA2010-6HL32-0CA0 and how is it quoted for volume purchases?","answer":"This part is sourced through independent distribution channels and is quoted to order against an RFQ. Availability and current pricing are confirmed at the time of quotation — volume inquiries receive a tailored response."},{"question":"What are the key ratings for 3VA2010-6HL32-0CA0?","answer":"It is a 3-pole MCCB with 100 A rated continuous current (holds to 50 °C), an ETU320 electronic trip unit, and breaking capacities of 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4 kA at 690 V."},{"question":"What is the depth of 3VA2010-6HL32-0CA0?","answer":"The depth is 86 mm. Width is 105 mm, height is 181 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0CA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HL32-0CA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}