{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HL32-0CL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HL32-0CL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0CL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0CL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-6HL32-0CL0, molded case circuit breaker, 3-pole, 100 A, 242 kA at 240 V, line protection, ETU320 release, with undervoltage release and auxiliary switches.","salesMarkdown":"The Siemens SENTRON 3VA2010-6HL32-0CL0 is a 3-pole molded case circuit breaker rated for 100 A continuous current, built for line protection duty. At 415 V it still breaks 187 kA, so it's sized for high-fault panels feeding motor control centers or distribution boards where the utility transformer is close. The 100 A rating holds flat from 40 °C to 50 °C — no derating needed in a warm panel. It starts stepping down at 55 °C: 96.25 A, then 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. If your enclosure runs hot, that derating curve is what tells you whether this frame size works or you need to bump up. The rated insulation voltage is 800 V, so it's comfortable in 480 V and 600 V systems with headroom. It's a straight line-protection device: overcurrent and short-circuit only. The auxiliary contact block includes 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch (HQ type), so you get status feedback for a PLC or alarm panel without adding a separate module. ## Panel integration Dimensions: 105 mm wide, 181 mm tall, 86 mm deep — fits a 3-pole MCCB footprint common across the SENTRON 3VA family. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C.","metaTitle":"Siemens 3VA2010-6HL32-0CL0 MCCB 100A, 242kA at 240V","metaDescription":"Siemens SENTRON 3VA2010-6HL32-0CL0 molded case circuit breaker, 100A rated continuous current, 242kA breaking at 240V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"16 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-6HL32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB24","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"4","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=283617&mlfb=3VA2010-6HL32-0CL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0CL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-6HL32-0CL0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of this MCCB?","answer":"242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4 kA at 690 V."},{"question":"What trip unit does this breaker use?","answer":"It uses an ETU320 electronic trip unit — line protection only, no communication or voltage trigger."},{"question":"What auxiliary contacts are included?","answer":"2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch (HQ type)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0CL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HL32-0CL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}