{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HL32-0HA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HL32-0HA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0HA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0HA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-6HL32-0HA0, molded case circuit breaker, 3-pole, 100 A, line protection, ETU320 electronic release, shunt trip, 242 kA at 240 V.","salesMarkdown":"The Siemens SENTRON 3VA2010-6HL32-0HA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a rated continuous current Iu of 100 A and a rated insulation voltage Ui of 800 V. The 242 kA interrupting capacity at 240 V and 187 kA at 415 V mean this breaker handles high-fault-current scenarios typical in industrial main feeders or large motor control centers — it safely clears a bolted fault without upstream devices needing to trip, which is the core of selective coordination. The breaker measures 105 mm wide, 181 mm high, and 86 mm deep — a standard SENTRON 3VA footprint that drops into existing Siemens switchboard or panel cutouts. No auxiliary contacts are fitted, and there is no communication module, so this is a standalone line-protection device. The shunt trip (STL) design of the auxiliary release allows remote tripping via a separate control voltage, useful for emergency-stop circuits or interlocking with a downstream contactor. The integrated auxiliary trip is order code 3VA9688-0BL30. The breaker carries 100 A continuously up to 50 °C ambient. Above that, derating applies: 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. The maximum operating temperature is 70 °C; storage range is -40 °C to 80 °C. In a hot panel — say a motor control center near a dryer section — the 85 A ceiling at 70 °C is the real limit, not the 100 A nameplate.","metaTitle":"Siemens 3VA2010-6HL32-0HA0 SENTRON MCCB, 100 A, 3-Pole, 242","metaDescription":"Siemens SENTRON 3VA2010-6HL32-0HA0 molded case circuit breaker, 100 A rated, 3-pole, line protection, ETU320 release, shunt trip, 242 kA at 240 V. Current lifecycle. Quoted to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"13.5 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-6HL32-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL30","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=254754&mlfb=3VA2010-6HL32-0HA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0HA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2010-6HL32-0HA0?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is 3VA2010-6HL32-0HA0's listed depth?","answer":"The depth is 86 mm."},{"question":"What is 3VA2010-6HL32-0HA0's listed width?","answer":"The width is 105 mm."},{"question":"Will 3VA2010-6HL32-0HA0 drop into a panel specified around 3VA1110-5EE32-0JA0 without rewiring?","answer":"The 3VA2010-6HL32-0HA0 shares the same SENTRON 3VA footprint (105 mm wide, 181 mm high, 86 mm deep) and 3-pole form factor, so it fits the same panel cutout and bus connections. However, the trip unit (ETU320 vs. the 3VA1110's release) and the shunt trip integration differ — verify the control wiring for the shunt trip (STL) matches the existing circuit, as the auxiliary release design may require a different control voltage or wiring scheme."},{"question":"What compliance documentation does this brand provide for 3VA2010-6HL32-0HA0?","answer":"Siemens SENTRON MCCBs typically carry UL 489, CSA C22.2 No. 5, and IEC 60947-2 certifications, plus RoHS and REACH declarations. Specific documentation for this order code is available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0HA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HL32-0HA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}