{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HL32-0HL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HL32-0HL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0HL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0HL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON molded case circuit breaker, 3VA2010-6HL32-0HL0, 3-pole, 100 A, 242 kA at 240 V AC, ETU320 trip unit, shunt trip, auxiliary switches.","salesMarkdown":"The Siemens SENTRON 3VA2010-6HL32-0HL0 is a 3-pole molded case circuit breaker rated for 100 A continuous current at 40 °C, with a breaking capacity of 242 kA at 240 V AC — enough to handle high-fault utility feeds or transformer secondaries without cascading upstream. Above that it derates linearly: 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. If your panel runs hot — near a drive or transformer — factor the 70 °C ceiling into your load calculation. Maximum power loss is 13.5 W, manageable for standard enclosure thermal budgets. Short-circuit performance varies with system voltage: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4 kA at 690 V.","metaTitle":"Siemens SENTRON 3VA2010-6HL32-0HL0 MCCB, 100 A, 242 kA at 24","metaDescription":"Siemens SENTRON 3VA2010-6HL32-0HL0 molded case circuit breaker, 3-pole, 100 A rated current, 242 kA breaking capacity at 240 V AC. Active production, quoted to order. Sourced throu","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"4 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"13.5 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2010-6HL32-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL30","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"4","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=229024&mlfb=3VA2010-6HL32-0HL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0HL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-6HL32-0HL0 and how is it quoted?","answer":"This MCCB is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings of 3VA2010-6HL32-0HL0?","answer":"It is a 3-pole MCCB rated 100 A continuous at 40 °C, with breaking capacity of 242 kA at 240 V AC, 187 kA at 415 V, and 4 kA at 690 V. It uses an ETU320 electronic trip unit and includes a shunt trip and auxiliary contact pack."},{"question":"Does 3VA2010-6HL32-0HL0 include a shunt trip and auxiliary contacts?","answer":"Yes, it comes with a shunt trip release (STL) and a factory-integrated auxiliary contact block: 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0HL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HL32-0HL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}