{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HL32-0JA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HL32-0JA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0JA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0JA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2010-6HL32-0JA0, 100 A continuous, 3-pole, line protection, shunt trip (STL), 242 kA at 240 V.","salesMarkdown":"The Siemens 3VA2010-6HL32-0JA0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C through 70 °C — no derating needed up to that ceiling. That flat thermal curve is the spec that decides the panel fill: if your bus is sized for 100 A and the enclosure runs warm, this breaker holds its rating without a bump in frame size. Three poles, line-protection design (not motor-protection curve), with an integrated shunt trip (STL) for remote tripping. The shunt trip is factory-fitted — no field-kit wiring, no auxiliary power module to source separately. If your safety circuit or emergency-stop chain requires a voltage-triggered opening, this variant delivers it out of the box. Breaking capacity is the other headline: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V. The 3 kA at 690 V is a reminder that this is a 3-pole breaker on a 690 V line; if your system runs 690 V phase-to-phase, the interrupting rating drops sharply, so verify coordination with the upstream device. ## Sourcing and lifecycle — active, no end-of-life signal The shunt trip coil itself draws power only during the trip event, not continuously, so it adds negligible heat to the steady-state calculation. That 86 mm depth is the front-to-back dimension including the arc chamber and terminals — important when the back panel has a gland plate or a rear-mounted busbar that limits protrusion. The 105 mm width is standard for a 3-pole 100 A frame in the 3VA2 family; it occupies three 35 mm DIN spaces if mounted on a DIN rail, or bolts directly to a mounting plate via the factory slots. The auxiliary release is a shunt trip (STL); verify the control voltage matches your trip circuit before wiring.","metaTitle":"Siemens 3VA2010-6HL32-0JA0 SENTRON MCCB, 100 A, 3-Pole, Shun","metaDescription":"Siemens 3VA2010-6HL32-0JA0 SENTRON molded case circuit breaker. 100 A continuous, 3-pole, line protection, shunt trip (STL). Breaking capacity 242 kA at 240 V. Active production. S","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20106HL320AA0","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=491506&mlfb=3VA2010-6HL32-0JA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HL32-0JA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this MCCB at 240 V?","answer":"242 kA at 240 V. At 415 V and 440 V it is 187 kA, at 500 V it is 121 kA, and at 690 V it is 3 kA."},{"question":"Does this breaker include a shunt trip?","answer":"Yes, it has a factory-fitted shunt trip (STL) for remote voltage-triggered opening. No undervoltage release or ground-fault monitoring on this variant."},{"question":"Where can I buy 3VA2010-6HL32-0JA0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HL32-0JA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HL32-0JA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}