{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HN32-0CL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HN32-0CL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HN32-0CL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HN32-0CL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-6HN32-0CL0, molded case circuit breaker, 3-pole, 100 A continuous rating, 242 kA interrupting at 240 V, line protection design with undervoltage release.","salesMarkdown":"The Siemens 3VA2010-6HN32-0CL0 is a SENTRON molded case circuit breaker rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed as the panel warms up near the top of the enclosure. Three-pole design with a trip indicator and an undervoltage release (UVR) built in. A voltage dip on the control supply drops the breaker open. Interrupting capacity hits 242 kA at 240 V and still 187 kA at 415 V, meaning it can sit at the main distribution point in a high-fault plant without needing a current-limiting upstream breaker. ## Panel fit and footprint Dimensions are 105 mm wide, 181 mm tall, 86 mm deep — a standard SENTRON 3VA2 frame that bolts into a panel on a mounting plate or DIN-rail adapter. The 86 mm depth leaves room behind the gland plate for cable bends. Auxiliary switch complement is two auxiliary switches plus one trip alarm and one electrical alarm switch (HQ design), so the PLC gets a dedicated fault signal without sharing contacts. Maximum power loss of 16 W at rated load keeps the internal enclosure temperature rise manageable — factor it into your thermal budget if the breaker shares a compartment with drives.","metaTitle":"Siemens 3VA2010-6HN32-0CL0 SENTRON MCCB, 100 A, 3-Pole, 242","metaDescription":"Siemens 3VA2010-6HN32-0CL0 SENTRON molded case circuit breaker, 100 A rated, 3-pole, 242 kA at 240 V. Current lifecycle stage. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"1 200 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"16 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20106HN320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB24","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=167782&mlfb=3VA2010-6HN32-0CL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HN32-0CL0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HN32-0CL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HN32-0CL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}