{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HN32-0DH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HN32-0DH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HN32-0DH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HN32-0DH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-6HN32-0DH0, 3-pole molded case circuit breaker, 100 A rated continuous current, line protection design, 242 kA breaking capacity at 240 V, built-in undervoltage release, auxiliary switches.","salesMarkdown":"At 415 V and 440 V it still holds 187 kA, dropping to 121 kA at 500 V, and 3 kA at 690 V. This is a breaker built for heavy industrial fault duty, not a light commercial branch device. ## Fault duty and selectivity At 690 V the 3 kA rating is lower, so verify coordination if the breaker is applied on a 690 V system with significant fault potential. ## What's on the frame The UVR means the breaker drops out if control voltage is lost, which is standard for emergency-stop chains and safety circuits. The trip indicator shows a mechanical flag when the breaker has tripped on fault, not just been switched off. Power loss is 16 W maximum at rated load, which is modest for a 100 A breaker — helps keep enclosure internal temperature down.","metaTitle":"Siemens 3VA2010-6HN32-0DH0 SENTRON MCCB, 100 A, 3-Pole, 242","metaDescription":"Siemens 3VA2010-6HN32-0DH0 SENTRON molded case circuit breaker, 100 A continuous, 3-pole, 242 kA breaking at 240 V. Current lifecycle stage. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"1 200 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"16 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20106HN320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=123403&mlfb=3VA2010-6HN32-0DH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HN32-0DH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-6HN32-0DH0 and get a price?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time."},{"question":"What is the breaking capacity of 3VA2010-6HN32-0DH0 at different voltages?","answer":"242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V."},{"question":"Does the 3VA2010-6HN32-0DH0 include an undervoltage release?","answer":"Yes, this order code includes an undervoltage release (UVR) as the auxiliary release, plus two auxiliary switches and one trip alarm switch."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HN32-0DH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HN32-0DH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}