{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HN36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HN36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HN36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HN36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-6HN36-0AA0, molded case circuit breaker, 100 A, 3-pole, ETU350 electronic trip unit, line protection, 242 kA at 240 V, 187 kA at 415 V.","salesMarkdown":"The Siemens SENTRON 3VA2010-6HN36-0AA0 is a 100 A molded case circuit breaker with an ETU350 electronic trip unit, built for line protection in 3-pole configurations. The 242 kA interrupting rating at 240 V and 187 kA at 415 V mean this breaker handles high-fault-current scenarios common in industrial distribution — think main or feeder duty where upstream transformer capacity can drive massive short-circuit current. The 100 A rating holds flat across the full -25 °C to 70 °C operating range, so no derating curve to chase in a warm panel. The 3VA2010-6HN36-0AA0 measures 105 mm wide by 181 mm tall by 86 mm deep — a standard SENTRON 3VA footprint that fits existing 3VA panel cutouts and bus-bar arrangements. An optional motor drive (Product Extension / Optional / Motor Drive: Yes) allows remote switching if the design calls for it. ## Trip unit and coordination Rated insulation voltage is 800 V, so it's comfortable on 480/277 V or 600 V systems. Maximum power loss is 13.5 W — a modest thermal load in a ventilated enclosure.","metaTitle":"Siemens 3VA2010-6HN36-0AA0 SENTRON MCCB, 100 A, 3-Pole, ETU3","metaDescription":"Siemens SENTRON 3VA2010-6HN36-0AA0 molded case circuit breaker, 100 A, 3-pole, ETU350 release. 242 kA at 240 V, 187 kA at 415 V. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"100 A","Ground-Fault Monitoring Version":"Without","Tension assignée d'isolement Ui":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","reference code / acc. to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"1 200 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Max. rated operational current of the frame size":"100 A","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/43e7ec1cfae405468596877f2657a9c1.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=308226&mlfb=3VA2010-6HN36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HN36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3VA2010-6HN36-0AA0 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings for 3VA2010-6HN36-0AA0?","answer":"It is a 100 A, 3-pole molded case circuit breaker with an ETU350 electronic trip unit. Interrupting ratings are 242 kA at 240 V, 187 kA at 415 V, and 3 kA at 690 V."},{"question":"What is the depth of 3VA2010-6HN36-0AA0?","answer":"The depth is 86 mm (3.39 in)."},{"question":"What is the width of 3VA2010-6HN36-0AA0?","answer":"The width is 105 mm (4.13 in)."},{"question":"Will 3VA2010-6HN36-0AA0 drop into a panel specified for 3VA2010-8HL42-0AA0?","answer":"Both are 3VA2010 frame breakers sharing the same 105 x 181 x 86 mm footprint, so they will mechanically fit the same panel cutout and bus-bar arrangement. However, the 8HL42 variant uses a different trip unit and interrupting rating; verify the protection coordination before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HN36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HN36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}