{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HN36-0HH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HN36-0HH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HN36-0HH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HN36-0HH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2, molded case circuit breaker, 3-pole, 100 A, 242 kA at 240 V AC, line protection, shunt trip (STL), 2 aux + 1 trip alarm switch HQ.","salesMarkdown":"The Siemens 3VA2010-6HN36-0HH0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C up to 70 °C — no derating needed in a warm panel. Breaking capacity is the headline number here: 242 kA at 240 V AC, 187 kA at 415 V, and still 121 kA at 500 V. That puts it in the high-interrupting category — it clears a fault without the arc re-striking, and it gives you selectivity headroom downstream. Power loss is 13.5 W maximum. Account for it in the thermal budget.","metaTitle":"Siemens 3VA2010-6HN36-0HH0 SENTRON MCCB, 100A, 242kA at 240V","metaDescription":"Siemens 3VA2010-6HN36-0HH0 SENTRON molded case circuit breaker, 100A continuous, 242kA breaking at 240V AC. 3-pole, line protection, shunt trip. Active production. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"1 200 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20106HN360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=165421&mlfb=3VA2010-6HN36-0HH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HN36-0HH0/alternatives.json"},"ai":{"faq":[{"question":"What is 3VA2010-6HN36-0HH0's listed depth?","answer":"86 mm (3.39 in). That is the depth from the mounting surface to the front of the breaker case."},{"question":"Will 3VA2010-6HN36-0HH0 drop into a panel specified around 3VA1110-5EF32-0AM0 without rewiring?","answer":"No. The 3VA2 frame (this part) and the 3VA1 frame have different mechanical platforms — lug positions, terminal spacing, and overall dimensions differ. Verify the mounting footprint against your panel layout before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HN36-0HH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HN36-0HH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}