{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6HN46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6HN46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6HN46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HN46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-6HN46-0AA0, molded case circuit breaker, 4-pole, 100 A rated continuous current, 242 kA breaking capacity at 240 V AC.","salesMarkdown":"Rated 100 A continuous current with four poles, it handles fault interruption up to 242 kA at 240 V — that rating means it clears high-energy faults on the line side without upstream damage, a key spec for panel SCCR coordination. The ETU350 overcurrent release provides electronic trip adjustment, giving selectivity flexibility downstream. ## Breaking capacity across voltages — what it means for your system Breaking capacity drops with system voltage: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V. Four-pole MCCB of this width typically occupies a standard MCCB slot in a distribution panel; the 140 mm width matches the common footprint for a 4-pole 100 A frame. Front IP40 protection means it is splash-safe from the front but not sealed — keep it inside the enclosure, not in a washdown zone.","metaTitle":"Siemens 3VA2010-6HN46-0AA0 SENTRON MCCB, 100 A, 4-Pole, 242","metaDescription":"Siemens SENTRON 3VA2010-6HN46-0AA0 molded case circuit breaker, 100 A rated, 4-pole, 242 kA breaking at 240 V. Active production. Sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"1 200 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"5.51 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"4","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 50%; 100%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/19322ddcb352d5ea1d12f18ca3c64334.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=323701&mlfb=3VA2010-6HN46-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6HN46-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2010-6HN46-0AA0 at 240 V?","answer":"242 kA at 240 V. At 415 V and 440 V it is 187 kA; at 500 V it is 121 kA; at 690 V it drops to 3 kA."},{"question":"How do I get pricing and availability for 3VA2010-6HN46-0AA0?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6HN46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6HN46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}