{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6JP36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6JP36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6JP36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6JP36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-6JP36-0AA0, molded case circuit breaker, 3-pole, 100 A, ETU550 electronic trip unit, line protection, 86 x 105 x 181 mm.","salesMarkdown":"Breaking capacity reaches 242 kA at 240 V and 187 kA at 415 V, so it clears high-fault conditions without cascading upstream — sized for a main breaker position in a 480 V panel feeding multiple motor loads. ## Panel footprint and integration At 13.5 W maximum power loss, the heat it dumps into the cabinet is modest — no forced cooling needed for a single unit, but group several breakers and check the enclosure's thermal budget.","metaTitle":"Siemens 3VA2010-6JP36-0AA0 SENTRON MCCB, 100 A, ETU550, 3-Po","metaDescription":"Siemens SENTRON 3VA2010-6JP36-0AA0 molded case circuit breaker. 100 A continuous, ETU550 release, 3-pole. Breaking capacity 242 kA at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9e55d71a003710bb665d679343148fb1.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=477971&mlfb=3VA2010-6JP36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6JP36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2010-6JP36-0AA0 at 415 V?","answer":"Rated 187 kA at 415 V, sufficient for high-fault industrial mains in a 400 V class panel."},{"question":"Where can I buy 3VA2010-6JP36-0AA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Submit a request for current pricing and availability."},{"question":"How does 3VA2010-6JP36-0AA0 compare to 3VA1110-5ED36-0AA0?","answer":"The 3VA1110-5ED36-0AA0 uses a thermal-magnetic trip unit; the 3VA2010-6JP36-0AA0 uses the ETU550 electronic trip, which offers adjustable curves and communication capability. Panel cutout dimensions are the same, so mechanical fit is identical, but the wiring and trip coordination differ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6JP36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6JP36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}