{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-6KQ36-0KA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-6KQ36-0KA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-6KQ36-0KA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6KQ36-0KA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-6KQ36-0KA0, molded case circuit breaker, 3-pole, 100 A rated, breaking capacity 242 kA at 240 V AC, 187 kA at 415/440 V, with shunt trip and communication function.","salesMarkdown":"The Siemens SENTRON 3VA2010-6KQ36-0KA0 is a 3-pole molded case circuit breaker (MCCB) rated at 100 A continuous at ambient temperatures from 40 °C up to 70 °C — meaning no derating is needed across the typical panel temperature range. The breaking capacity is 242 kA at 240 V AC, dropping to 187 kA at 415 V and 440 V, and 121 kA at 500 V; at 690 V it still interrupts 3 kA. The 3-pole form factor fits a standard 3-module MCCB slot. The shunt trip wiring and communication bus (if used) occupy the auxiliary terminal space on the left side — plan for a 10 mm clearance on that side for cable bending radius. ## Ground-fault and monitoring features The breaker includes a ground-fault monitoring version using summation current formation on the L-conductor, so it detects residual currents without an external core-balance transformer. The communication function and other measurement function allow integration into a higher-level monitoring system — useful for predictive maintenance or energy accounting on a feeder. Power loss is 13.5 W maximum, which is modest for a 100 A MCCB and keeps the panel heat rise manageable.","metaTitle":"Siemens 3VA2010-6KQ36-0KA0 SENTRON MCCB, 100 A, 3-pole, 242","metaDescription":"Siemens SENTRON 3VA2010-6KQ36-0KA0 molded case circuit breaker, 100 A rated, 3-pole, breaking capacity 242 kA at 240 V AC. Current production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"160 A","Minimum":"20 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Initial Value":"20 A","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Full-Scale Value":"100 A","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"13.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Of The Supplied Basic Switch":"3VA20106KQ360AA0","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Summation current formation L-conductor","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU860","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL33","Product Function / Grounding Protection":"Yes","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSIG","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1428093&mlfb=3VA2010-6KQ36-0KA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-6KQ36-0KA0/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3VA2010-6KQ36-0KA0 and how is it quoted for volume purchases?","answer":"The part is sourced through independent distribution and quoted to order against an RFQ. Volume pricing and lead time are confirmed at quote time — submit an RFQ for your quantity."},{"question":"What is 3VA2010-6KQ36-0KA0's listed depth?","answer":"The depth is 86 mm."},{"question":"What is 3VA2010-6KQ36-0KA0's listed width?","answer":"The width is 105 mm."},{"question":"Will 3VA2010-6KQ36-0KA0 drop into a panel specified around 5SQ2370-2YA05 without rewiring?","answer":"The 3VA2010-6KQ36-0KA0 is a different series from the 5SQ2370 family. While both are 3-pole MCCBs, the footprint, terminal spacing, and auxiliary wiring differ — a direct drop-in is not guaranteed. Verify the mounting dimensions and terminal layout against your existing panel cutout and bus bars before specifying."},{"question":"What compliance documentation does this brand provide for 3VA2010-6KQ36-0KA0?","answer":"The SENTRON series carries UL, CSA, and IEC certifications. RoHS and REACH declarations are available from the manufacturer upon request. Specific documentation (declaration of conformity, test certificates) can be included with the shipment if requested at order time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-6KQ36-0KA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-6KQ36-0KA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}