{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-7HL36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-7HL36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-7HL36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-7HL36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA series, molded case circuit breaker (MCCB), 3VA2010-7HL36-0AA0, 3-pole, 100 A rated current, 330 kA interrupting capacity at 240 V AC, ETU320 electronic trip unit, line protection.","salesMarkdown":"The Siemens SENTRON 3VA2010-7HL36-0AA0 is a 3-pole molded case circuit breaker rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Its interrupting capacity hits 330 kA at 240 V AC, dropping to 242 kA at 415 V and 440 V, then 187 kA at 500 V, and 3 kA at 690 V. ## What the interrupting ratings mean for panel design The 330 kA at 240 V is the headline number, but the real-world selectivity study will use the 242 kA at 415 V or 440 V — that's the common industrial distribution voltage in most markets outside North America. At 500 V the breaker still holds 187 kA, which covers most motor control center bus faults. The 3 kA at 690 V is a steep drop; at that voltage the breaker is essentially a load-break switch with overcurrent protection, not a high-fault device. Footprint is 105 mm wide, 181 mm tall, 86 mm deep — a standard 3-pole MCCB envelope that fits Siemens SENTRON 3VA mounting bases and busbar adapters. The IP40 front protection means the breaker face is sealed against tools and fingers, but the rear and sides rely on the enclosure for environmental sealing. No undervoltage release, no voltage trip, no communication module onboard; the optional motor drive (noted in the product extension field) can be added for remote tripping or re-closing.","metaTitle":"Siemens 3VA2010-7HL36-0AA0 SENTRON MCCB, 100 A, 3-Pole, 330","metaDescription":"Siemens SENTRON 3VA2010-7HL36-0AA0 molded case circuit breaker, 100 A rated, 3-pole, 330 kA interrupting at 240 V. ETU320 release, IP40 front. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"7.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"100 A","Ground-Fault Monitoring Version":"Without","Tension assignée d'isolement Ui":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","reference code / acc. to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"C","Max. rated operational current of the frame size":"100 A","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/41eb191eddf0f2cf78e48060b4bc4827.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=260341&mlfb=3VA2010-7HL36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-7HL36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the 3VA2010-7HL36-0AA0 interrupting capacity at 240 V?","answer":"330 kA at 240 V AC, the highest rating on this breaker. At 415 V and 440 V it is 242 kA, at 500 V it is 187 kA, and at 690 V it is 3 kA."},{"question":"Where can I buy the 3VA2010-7HL36-0AA0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."},{"question":"Does the 3VA2010-7HL36-0AA0 have an electronic or thermal-magnetic trip unit?","answer":"It uses the ETU320 electronic trip unit, which provides adjustable protection curves — typically LSIG (long-time, short-time, instantaneous, ground fault) or LSI depending on configuration."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-7HL36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-7HL36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}