{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-7JQ36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-7JQ36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-7JQ36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-7JQ36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2010-7JQ36-0AA0, molded case circuit breaker, 3-pole, 100 A, 330 kA at 240 V interrupting, line protection design, with communication function.","salesMarkdown":"The interrupting capacity hits 330 kA at 240 V, 242 kA at 415 V and 440 V, and 187 kA at 500 V; at 690 V it drops to 3 kA, so for 690 V applications you need to check coordination with upstream devices. The breaker includes a communication function for integration into a monitored system and has ground-fault monitoring via summation current formation on the L-conductor. That 105 mm width across 3 poles is the standard SENTRON 3VA footprint — it fits the same DIN-rail or mounting-plate cutout as other breakers in the family. The maximum power loss is 7.7 W, which is modest for a 100 A frame and keeps heat buildup manageable in a sealed enclosure. ## Protection and monitoring features The ground-fault monitoring uses summation current formation on the L-conductor, which detects leakage by summing the phase currents; it does not require a separate neutral CT. ## Environmental limits That covers most indoor industrial and commercial environments, including unheated warehouses in cold climates. The -25 °C lower operating limit means it can be installed in a non-conditioned space in most temperate zones.","metaTitle":"Siemens 3VA2010-7JQ36-0AA0 SENTRON MCCB, 100 A, 3-Pole","metaDescription":"Siemens SENTRON 3VA2010-7JQ36-0AA0 molded case circuit breaker, 100 A continuous, 3-pole, 330 kA at 240 V interrupting. Current lifecycle. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Initial Value":"20 A","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Full-Scale Value":"100 A","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"7.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Summation current formation L-conductor","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU560","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Product Function / Grounding Protection":"Yes","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSIG","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2645a7a92c6789d7c032019827e34576.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=350131&mlfb=3VA2010-7JQ36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-7JQ36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-7JQ36-0AA0 and get a price?","answer":"This part is sourced to order through our independent distribution network. Submit an RFQ for current availability and pricing — we confirm both at quote time."},{"question":"What are the key ratings of 3VA2010-7JQ36-0AA0?","answer":"It is a 3-pole, 100 A continuous MCCB with 330 kA interrupting at 240 V, 242 kA at 415 V and 440 V, and 187 kA at 500 V. It includes communication and ground-fault monitoring."},{"question":"What is the depth of 3VA2010-7JQ36-0AA0?","answer":"The depth is 86 mm (3.39 in)."},{"question":"What is the width of 3VA2010-7JQ36-0AA0?","answer":"The width is 105 mm (4.13 in)."},{"question":"Will 3VA2010-7JQ36-0AA0 drop into a panel specified for 6ES7514-2DN03-0AB0?","answer":"No — 6ES7514-2DN03-0AB0 is a Siemens S7-1500 CPU, not a circuit breaker. The 3VA2010-7JQ36-0AA0 is an MCCB for power distribution, so it serves a completely different function and cannot be swapped in without rewiring the entire panel."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-7JQ36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-7JQ36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}