{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-7KP46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-7KP46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-7KP46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-7KP46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2, molded case circuit breaker, 4-pole, 100 A, ETU850 electronic trip unit, line protection, 330 kA at 240 V, IP40 front.","salesMarkdown":"## What this 4-pole 100 A MCCB carries The Siemens SENTRON 3VA2010-7KP46-0AA0 is a 4-pole molded case circuit breaker rated for 100 A continuous at 40 °C through 70 °C — no derating needed across that band, which simplifies panel schedules in warm enclosures. The ETU850 electronic trip unit handles line protection duty with communication and measurement functions onboard, so it reports current draw and trip events back to the control system without a separate metering module.","metaTitle":"Siemens 3VA2010-7KP46-0AA0 SENTRON MCCB, 100A, 4-Pole, ETU85","metaDescription":"Siemens 3VA2010-7KP46-0AA0 SENTRON molded case circuit breaker, 100 A continuous, 4-pole, ETU850 electronic trip unit, 330 kA at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"5.51 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"4","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"7.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU850","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 100%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/181828dc6fb907597879f1c1f8bac0cc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=289433&mlfb=3VA2010-7KP46-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-7KP46-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2010-7KP46-0AA0 and what is the lead time?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number published here."},{"question":"What is the closest functional second-source for 3VA2010-7KP46-0AA0?","answer":"The peer 3VA2110-8HN32-0AA0 shares the same 4-pole, 100 A frame and ETU850 trip platform, but it carries a different breaking capacity curve and accessory configuration. Verify the SCCR requirements and auxiliary contact count before substituting — the footprint is the same, but the protection coordination may shift."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-7KP46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-7KP46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}