{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2010-8KP36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2010-8KP36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2010-8KP36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2010-8KP36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA series, Molded case circuit breaker, 3VA2010-8KP36-0AA0, 3-pole, 100 A rated, ETU850 electronic trip unit, 440 kA breaking capacity at 240 V.","salesMarkdown":"The Siemens SENTRON 3VA2010-8KP36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to the top of the enclosure's thermal curve. The breaking capacity hits 440 kA at 240 V and still holds 330 kA at 415 V or 440 V, which puts it squarely in high-fault-duty main or feeder positions. At 690 V the breaker still interrupts 52.5 kA, which covers most 690 V industrial bus applications. For selective coordination studies, the ETU850 provides the adjustable I²t and short-time delay settings needed to cascade with downstream Sentron 3VA or 3VL breakers. The IP40 front protection is typical for panel-mount — no special gasketing needed for dry indoor switchgear. Dimensions are 105 mm wide × 181 mm tall × 86 mm deep — standard 3-pole MCCB footprint for the 3VA platform. No undervoltage release or voltage trip module fitted from factory, but the optional motor drive extension is listed as available. The breaker ships without a ground-fault monitoring module, so if you need GF protection, that's an add-on accessory. Communication function is onboard, so it can talk to a PLC or BMS directly via the 3VA communication module interface.","metaTitle":"Siemens SENTRON 3VA2010-8KP36-0AA0 MCCB, 100 A, 3-Pole, 440","metaDescription":"Siemens SENTRON 3VA2010-8KP36-0AA0 molded case circuit breaker, 100 A continuous, 3-pole, ETU850 trip unit, breaking capacity 440 kA at 240 V. Active production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"440 kA","at 415 V":"330 kA","at 440 V":"330 kA","at 500 V":"220 kA","at 690 V":"52.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"7.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Courant permanent assigné Iu":"100 A","Ground-Fault Monitoring Version":"Without","Tension assignée d'isolement Ui":"800 V","Design Of The Overcurrent Release":"ETU850","protection class IP / on the front":"IP40","reference code / acc. to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Neutral conductors / upgradeable/retrofittable":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"L","Max. rated operational current of the frame size":"100 A","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/32af6a1694c3b4af6734b143d8d7cb2b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=375213&mlfb=3VA2010-8KP36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2010-8KP36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2010-8KP36-0AA0 at different voltages?","answer":"Breaking capacity is 440 kA at 240 V, 330 kA at 415 V and 440 V, 220 kA at 500 V, and 52.5 kA at 690 V."},{"question":"What trip unit does this MCCB use?","answer":"It uses the ETU850 electronic trip unit, which provides adjustable overload and short-circuit protection curves with communication capability."},{"question":"Where can I buy 3VA2010-8KP36-0AA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2010-8KP36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2010-8KP36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}