{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2025-6HL32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2025-6HL32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2025-6HL32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2025-6HL32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2025-6HL32-0AA0, molded case circuit breaker, 3-pole, 25 A continuous, ETU320 release, 242 kA at 240 V.","salesMarkdown":"The Siemens 3VA2025-6HL32-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for 25 A continuous current with a 3-pole configuration and an ETU320 electronic trip unit. At 415 V it still breaks 187 kA, so it handles the main feeder or a big motor branch where the transformer is right next door. The 25 A rating holds steady from 40 °C all the way up to 70 °C ambient — no derating curve to chase in a hot enclosure. That's unusual for a breaker this size; most start dropping current above 40 °C. The ETU320 release gives you adjustable long-time, short-time, and instantaneous pickups, so you can coordinate selectively downstream without nuisance tripping on motor inrush. ## Where it goes and how it fits The 105 mm width is a standard 3-pole footprint — it'll drop into the same slot as most SENTRON 3VA family breakers without rewiring the bus bars.","metaTitle":"Siemens 3VA2025-6HL32-0AA0 SENTRON MCCB, 25 A, 242 kA at 240","metaDescription":"Siemens SENTRON 3VA2025-6HL32-0AA0 molded case circuit breaker, 25 A rated, 3-pole, 242 kA breaking at 240 V. ETU320 release. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"300 A","Minimum":"38 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3 kA","at 40 °C":"25 A","at 45 °C":"25 A","at 50 °C":"25 A","at 55 °C":"25 A","at 60 °C":"25 A","at 65 °C":"25 A","at 70 °C":"25 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"0.84 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"25 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=307787&mlfb=3VA2025-6HL32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2025-6HL32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this MCCB at 240 V?","answer":"It's rated 242 kA at 240 V, which covers high-fault-current service entrance or main feeder applications."},{"question":"Does the 3VA2025-6HL32-0AA0 drop into a panel wired for the 3VA1110-5EF32-0AM0?","answer":"Both are 3-pole SENTRON MCCBs on the same DIN-rail footprint, so the mechanical fit and bus-bar spacing are identical. The key difference is the trip unit — the 3VA2025 uses an ETU320 electronic release, while the 3VA1110 typically uses a thermal-magnetic release. If the panel was designed for a thermal-magnetic breaker, verify the control wiring and any communication harness before swapping."},{"question":"Where can I buy the 3VA2025-6HL32-0AA0 and how is it quoted?","answer":"It's sourced to order through independent distribution. Submit an RFQ for current pricing and availability — volume and project quotes are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2025-6HL32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2025-6HL32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}