{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2025-6HM36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2025-6HM36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2025-6HM36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2025-6HM36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2025-6HM36-0AA0, molded case circuit breaker, line protection, 3-pole, 25 A rated continuous current, 242 kA breaking capacity at 240 V.","salesMarkdown":"The Siemens SENTRON 3VA2025-6HM36-0AA0 is a 3-pole molded case circuit breaker (MCCB) designed for line protection, carrying a rated continuous current of 25 A across its full operating temperature range from -25 °C to 70 °C with no derating needed. Its breaking capacity is substantial: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V — meaning it can safely interrupt high fault currents across common industrial voltage levels without upstream cascading. The trip indicator is absent on this variant, and there is no undervoltage release or communication function — it is a straightforward thermal-magnetic MCCB for basic overcurrent and short-circuit protection.","metaTitle":"Siemens 3VA2025-6HM36-0AA0 SENTRON MCCB, 25 A, 3-Pole","metaDescription":"Siemens SENTRON 3VA2025-6HM36-0AA0 molded case circuit breaker, 25 A continuous, 3-pole, 242 kA at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"300 A","Minimum":"38 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3 kA","at 40 °C":"25 A","at 45 °C":"25 A","at 50 °C":"25 A","at 55 °C":"25 A","at 60 °C":"25 A","at 65 °C":"25 A","at 70 °C":"25 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Initial Value":"15 A","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Full-Scale Value":"25 A","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"0.84 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Summation current formation L-conductor","Continuous Current / Rated Value":"25 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU330","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"Yes","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LIG","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8488399d42bd590521594ed8a5aaecc0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=138224&mlfb=3VA2025-6HM36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2025-6HM36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2025-6HM36-0AA0?","answer":"Submit an RFQ through the storefront — pricing and stock are confirmed at quote time through independent distribution channels."},{"question":"What is the breaking capacity of 3VA2025-6HM36-0AA0 at 240 V?","answer":"242 kA at 240 V, with 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3 kA at 690 V."},{"question":"Will 3VA2025-6HM36-0AA0 drop into a panel specified for 3VA1110-5ED36-0AA0?","answer":"Both are 3-pole SENTRON MCCBs with similar frame sizes, but the 3VA1110 series has different breaking capacity and accessory configurations — verify the cutout dimensions and mounting pattern against your panel layout before substitution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2025-6HM36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2025-6HM36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}