{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2040-7JQ36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2040-7JQ36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2040-7JQ36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2040-7JQ36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2040-7JQ36-0AA0, molded case circuit breaker, 3-pole, 40 A, 330 kA at 240 V, ETU560 release, line protection.","salesMarkdown":"## What this MCCB does for a 40 A feeder The Siemens SENTRON 3VA2040-7JQ36-0AA0 is a 3-pole molded case circuit breaker rated for 40 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. It carries a 330 kA breaking capacity at 240 V, dropping to 242 kA at 415 V and 440 V, then 187 kA at 500 V, and 3 kA at 690 V. That makes it a high-interrupting-capacity feeder breaker for large transformers or bus ties where fault currents are severe. ## ETU560 release and ground-fault monitoring The overcurrent release is an ETU560 electronic trip unit with adjustable long-time pickup and delay (tr from 0.5 to 25) and short-time delay (tsd up to 0.5 s). Communication function is built in, so this breaker can report status and trip events to a BMS or SCADA system without an add-on module. Front protection is IP40, so it handles incidental tool contact but not washdown. Power loss is 2.2 W maximum, which keeps heat rise manageable in a crowded enclosure.","metaTitle":"Siemens 3VA2040-7JQ36-0AA0 SENTRON MCCB, 40 A, 3-Pole, 330 k","metaDescription":"Siemens SENTRON 3VA2040-7JQ36-0AA0 molded case circuit breaker, 40 A continuous, 3-pole, 330 kA breaking capacity at 240 V. Current lifecycle. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3 kA","at 40 °C":"40 A","at 45 °C":"40 A","at 50 °C":"40 A","at 55 °C":"40 A","at 60 °C":"40 A","at 65 °C":"40 A","at 70 °C":"40 A","Depth [in]":"3.4 in","Width [in]":"4.1 in","Height [in]":"7.1 in","Number of poles":"3","Product version":"Line protection","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"2.2 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-40 °C","Other Measurement Function":"No","Rated continuous current Iu":"40 A","Rated insulation voltage Ui":"800 V","Ground fault monitoring version":"Summation current formation L-conductor","Design of the overcurrent release":"ETU560","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"25","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"40 A","Adjustable response value current / lg max.":"40 A","Adjustable response value current / lg min.":"16 A","Adjustable response value current / li max.":"480 A","Adjustable response value current / li min.":"60 A","Adjustable response value current / lr min.":"16 A","Adjustable response value current / tg max.":"0.8 s","Adjustable response value current / tg min.":"0.05 s","Adjustable response value current / Isd max.":"400 A","Adjustable response value current / Isd min.":"24 A","Ground fault protection can be switched ON/OFF":"Yes","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LSIG","Switching capacity class of the circuit breaker":"C","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/26b29cb1361dc979e5f32d3c3f49cc72.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=351179&mlfb=3VA2040-7JQ36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2040-7JQ36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this MCCB at 415 V?","answer":"242 kA at 415 V, which is the same rating it carries at 440 V."},{"question":"Does the 3VA2040-7JQ36-0AA0 support communication?","answer":"Yes, communication function is built in, allowing integration with a BMS or SCADA system for status and trip reporting."},{"question":"Where can I buy 3VA2040-7JQ36-0AA0 and what is the price?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2040-7JQ36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2040-7JQ36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}