{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2063-5HL36-0CC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2063-5HL36-0CC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2063-5HL36-0CC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2063-5HL36-0CC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2063-5HL36-0CC0 molded case circuit breaker, 63 A continuous, 3-pole, line protection, 187 kA interrupting at 240 V, undervoltage release, 2 HQ auxiliary switches.","salesMarkdown":"The Siemens SENTRON 3VA2063-5HL36-0CC0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to 70 °C, which simplifies panel design in warm cabinets. Its interrupting capacity hits 187 kA at 240 V, 121 kA at 415 V, and 75.6 kA at 500 V, so it handles high-fault utility feeds or transformer secondaries. ## Interrupting capacity and what it means for your panel The drop to 3 kA at 690 V tells you this is a 240–500 V class breaker; don't spec it for 690 V main feeds unless the fault current is very low. ## Panel integration and wiring notes The breaker measures 105 mm wide, 181 mm high, and 86 mm deep — standard SENTRON 3VA2 footprint for a 3-pole frame. Two HQ auxiliary switches give dry-contact status; wire them back to the PLC input card for breaker position monitoring.","metaTitle":"Siemens 3VA2063-5HL36-0CC0 MCCB, 63 A, 3-Pole, Line Protecti","metaDescription":"Siemens SENTRON 3VA2063-5HL36-0CC0 molded case circuit breaker, 63 A continuous, 187 kA at 240 V, 3-pole, line protection, undervoltage release, active lifecycle. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"756 A","Minimum":"95 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"7.9 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20635HL360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB24","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=152389&mlfb=3VA2063-5HL36-0CC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2063-5HL36-0CC0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2063-5HL36-0CC0?","answer":"Submit an RFQ through this listing; we source and quote to order against independent distribution, and confirm current pricing and availability at quote time."},{"question":"What is the interrupting capacity of 3VA2063-5HL36-0CC0 at 240 V?","answer":"187 kA at 240 V, making it suitable for high-fault-current service-entrance or main-breaker positions."},{"question":"Does 3VA2063-5HL36-0CC0 include an undervoltage release?","answer":"Yes, it comes with an integrated undervoltage release (UVR) that trips the breaker when control voltage drops."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2063-5HL36-0CC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2063-5HL36-0CC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}