{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2063-5HN36-0HA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2063-5HN36-0HA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2063-5HN36-0HA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2063-5HN36-0HA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2063-5HN36-0HA0, molded case circuit breaker, 3-pole, 63 A, line protection, shunt trip (STL), breaking capacity 187 kA at 240 V.","salesMarkdown":"## SENTRON 3VA2 MCCB with integrated shunt trip It carries a shunt trip release (STL) as the auxiliary release — meaning it can be tripped remotely by applying a control voltage, which is useful for emergency-off circuits or interlocking schemes where you need to drop the breaker without a manual handle pull. Breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3 kA at 690 V. The breaker measures 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint that fits SENTRON 3VA2 mounting bases and busbar systems. The 86 mm depth (3.39 in) is shallow enough for most 600 mm deep enclosures without crowding the door or cable gutters. If you need UVR or GF protection, you would step to a different 3VA2 order code with those options built in. Maximum power loss is 5.4 W at rated current — negligible for panel heat budgeting.","metaTitle":"Siemens 3VA2063-5HN36-0HA0 SENTRON MCCB, 63 A, 3-Pole, Shunt","metaDescription":"Siemens SENTRON 3VA2063-5HN36-0HA0 molded case circuit breaker, 63 A, 3-pole, line protection with shunt trip (STL). Breaking capacity 187 kA at 240 V. Active production. Quoted to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"756 A","Minimum":"756 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"5.4 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20635HN360AA0","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=113031&mlfb=3VA2063-5HN36-0HA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2063-5HN36-0HA0/alternatives.json"},"ai":{"faq":[{"question":"Does this breaker have a shunt trip?","answer":"Yes, the auxiliary release is a shunt trip (STL), allowing remote tripping via a control voltage. There is no undervoltage release and no ground-fault monitoring on this variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2063-5HN36-0HA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2063-5HN36-0HA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}