{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2063-5HN36-0KA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2063-5HN36-0KA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2063-5HN36-0KA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2063-5HN36-0KA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2063-5HN36-0KA0, 63 A, 3-pole, ETU350 electronic trip unit, line protection, shunt trip (STL), 187 kA at 240 V, 86 x 105 x 181 mm.","salesMarkdown":"## What this 3VA2063-5HN36-0KA0 brings to a panel Breaking capacity hits 187 kA at 240 V AC and holds 121 kA at 415/440 V, then drops to 79 kA at 500 V and 3.4 kA at 690 V. The ETU350 release gives you adjustable long-time, short-time, and instantaneous pickup, plus ground-fault capability if you add the optional module. Rated 63 A from 40 °C through 50 °C; above that it derates linearly to 53.55 A at 70 °C. The 5.4 W max power loss is modest; no special ventilation required in a typical IP54 enclosure.","metaTitle":"Siemens 3VA2063-5HN36-0KA0 SENTRON MCCB, 63 A, 3-Pole, ETU35","metaDescription":"Siemens 3VA2063-5HN36-0KA0 SENTRON molded case circuit breaker, 63 A rated continuous current, 3-pole, ETU350 electronic trip unit, 187 kA at 240 V. Active production, sourced to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"3.4 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"60.6375 A","at 60 °C":"58.275 A","at 65 °C":"55.9125 A","at 70 °C":"53.55 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"5.4 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"63 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2063-5HN36-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL33","Design of the overcurrent release":"ETU350","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.4 s","Adjustable response value time / tsd min.":"0.02 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"63 A","Adjustable response value current / li max.":"756 A","Adjustable response value current / li min.":"756 A","Adjustable response value current / lr min.":"25 A","Adjustable response value current / Isd max.":"630 A","Adjustable response value current / Isd min.":"95 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LSI","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=146710&mlfb=3VA2063-5HN36-0KA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2063-5HN36-0KA0/alternatives.json"},"ai":{"faq":[{"question":"What is 3VA2063-5HN36-0KA0's listed depth (86 mm) on this component line?","answer":"The depth is 86 mm, width 105 mm, height 181 mm — standard 3VA2 footprint for DIN-rail or panel-mount installation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2063-5HN36-0KA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2063-5HN36-0KA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}