{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2063-6HL32-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2063-6HL32-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2063-6HL32-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2063-6HL32-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON molded case circuit breaker, 3VA2063-6HL32-0DL0, 3-pole, 63 A continuous, line protection, with undervoltage release, 242 kA at 240 V.","salesMarkdown":"## What this MCCB does for a panel The Siemens SENTRON 3VA2063-6HL32-0DL0 is a 3-pole molded case circuit breaker rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. A trip indicator gives visual confirmation of a fault trip without needing to open the door. This breaker carries a maximum breaking capacity of 756 A and a minimum of 95 A, but the real selection driver is the interrupting rating at system voltage. At 240 V it clears 242 kA — enough for high-fault service-entrance or large sub-distribution boards. At 415 V and 440 V the rating holds at 187 kA, dropping to 121 kA at 500 V. At 690 V the rating is 3 kA, which restricts this frame to low-fault 690 V applications or downstream positions with current-limiting upstream devices. The 86 mm depth, 105 mm width, and 181 mm height fit standard SENTRON panel cutouts; verify the mounting footprint against existing busbar spacing before committing the BOM line.","metaTitle":"Siemens 3VA2063-6HL32-0DL0 SENTRON MCCB, 63 A, 3-Pole, 242 k","metaDescription":"Siemens SENTRON 3VA2063-6HL32-0DL0 molded case circuit breaker, 63 A continuous, 3-pole, 242 kA breaking at 240 V. Line protection with undervoltage release. Current lifecycle. Sou","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"756 A","Minimum":"95 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"7.9 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA20636HL320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=79064&mlfb=3VA2063-6HL32-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2063-6HL32-0DL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2063-6HL32-0DL0 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here."},{"question":"What compliance documentation does this breaker carry?","answer":"As a current SENTRON product, it carries RoHS, REACH, UL, and IEC compliance documentation standard from Siemens. The specific certification marks are listed in the manufacturer's declaration pack; request the current compliance certificate at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2063-6HL32-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2063-6HL32-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}