{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2063-6HN32-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2063-6HN32-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2063-6HN32-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2063-6HN32-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2063-6HN32-0DA0, molded case circuit breaker, 3-pole, 63 A, 242 kA at 240 V, ETU350 release, undervoltage release, line protection.","salesMarkdown":"## MCCB with 242 kA interrupting capacity — what that means for your panel The Siemens SENTRON 3VA2063-6HN32-0DA0 is a 3-pole molded case circuit breaker rated for 63 A continuous current at 40 °C through 50 °C, with no derating needed across that band. Its interrupting capacity hits 242 kA at 240 V and 187 kA at 415 V — numbers that tell you this breaker is built for high-fault locations like transformer secondaries or large motor control centers where available fault current can exceed 100 kA. At 690 V it still clears 4 kA, so it handles most industrial line-to-line voltages in a mixed-voltage panel. ## Panel integration — dimensions and mounting The 3-pole footprint is standard for a 63 A frame; plan for a 105 mm wide slot in your enclosure layout. No auxiliary contacts are pre-wired — if you need alarm or status contacts, they must be added externally.","metaTitle":"Siemens 3VA2063-6HN32-0DA0 SENTRON MCCB, 63 A, 242 kA at 240","metaDescription":"Siemens SENTRON 3VA2063-6HN32-0DA0 molded case circuit breaker, 63 A rated, 242 kA breaking at 240 V, 3-pole, ETU350 release, undervoltage release. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"4 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"60.6375 A","at 60 °C":"58.275 A","at 65 °C":"55.9125 A","at 70 °C":"53.55 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"7.9 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"63 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2063-6HN32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"ETU350","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.4 s","Adjustable response value time / tsd min.":"0.02 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"63 A","Adjustable response value current / li max.":"756 A","Adjustable response value current / li min.":"756 A","Adjustable response value current / lr min.":"25 A","Adjustable response value current / Isd max.":"630 A","Adjustable response value current / Isd min.":"95 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LSI","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=326391&mlfb=3VA2063-6HN32-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2063-6HN32-0DA0/alternatives.json"},"ai":{"faq":[{"question":"Will 3VA2063-6HN32-0DA0 drop into a panel specified around 3VA1010-2ED32-0JA0?","answer":"No — the 3VA1010-2ED32-0JA0 is a smaller-frame MCCB with lower interrupting capacity. The 3VA2063 is physically larger (105 mm wide vs the 3VA1010's frame) and has a higher fault rating. Panel cutouts and bus connections would need to be re-evaluated."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2063-6HN32-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2063-6HN32-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}